(UURU&RQGLWLRQV
39
Servic
e In
forma
tion
Pinned track.
A “pinned track” occurs when a disk drive failure
temporarily prevents data from being destaged from
cache to disk. The next time the data on the pinned
track is accessed by the host, the data is destaged to
another disk location. The RAID technology and
dynamic spare disk drives of the disk array ensure full
recovery from disk drive failures and non-stop access
to user data.
Data can remain pinned in cache if it is not accessed
by the host following the pinned track condition.
Maintenance activities (for example, microcode
updates) require that all pinned tracks be cleared.
If an HP service representative encounters pinned
tracks during these activities, user assistance can be
required to access the data (for example, run DSF
Inspect, read and write specific data) to cause it to be
destaged to disk.
Emergency: fire, earthquake, flood, etc.
Pull the emergency power-off (EPO) switch. Refer to
the process outlined in “Emergency Power-Off” (page
31). Call the HP support center to have the EPO
switch reset.
ALARM LED is on.
If there is an ambient temperature problem in the area
(see “Specifications”, page 51), lower the room
temperature and call your HP support representative.
If the area temperature is not the obvious cause of the
alarm, call the HP support center for assistance.
FRQWLQXHG
7DEOH
(UURU&RQGLWLRQV
FRQWLQXHG
Error Condition
Recommended Action
Summary of Contents for Surestore XP256 - Disk Array
Page 1: ... 3 6XUH6WRUH LVN UUD 3 DPLOLDUL DWLRQ XLGH 2UGHU 1R 3ULQWHG LQ 86 KS ...
Page 20: ...20 2SWLRQDO 6RIWZDUH ...
Page 24: ...24 2SHUDWRU RQWURO 3DQHO LJXUH 2SHUDWRU RQWURO 3DQHO FRONT VIEW ...
Page 36: ...36 8VLQJ 5HPRWH RQWURO 6RIWZDUH ...
Page 66: ...66 FURQ PV DQG EEUHYLDWLRQV ...
Page 68: ...68 QGH 6SHFLILFDWLRQV HQYLURQPHQWDO 693 6ZLWFK SDQHO ...
Page 71: ......
Page 72: ... RS ULJKW HZOHWW 3DFNDUG RPSDQ 3ULQWHG LQ 86 2UGHU 1XPEHU PA5701 96013 ...