32
6. Shutdown the array using the front panel.
KEY DISPLAY
CANCEL CANCEL
“Ready”
MENU “Language”
– “View
Settings”
– “Shutdown”
ENTER “Confirm”
ENTER “Shutdown
Complete”
After shutdown has completed, push the on/off button to the off position completing the
shutdown. This will turn off power to all modules.
7. Disconnect all disk drive modules from the back plane. You do not need to remove them completely.
Just pull them out so that the cam handle is fully extended.
8. Pull the existing good controller and reset (disconnect and then re-connect) both batteries at the same
time. This will mean that the only copy of valid maps reside on the disk drive modules.
9. Install both controllers. Put the controller with the desired firmware into controller slot X.
10. Push the on/off button to the on position and allow the array to complete its initialization process. After
the initialization has completed, the front panel should say “Not Enough Disks”. Check the system state
using the key strokes below. The System state should be “Not Enough Disks” with a “Firmware
Needed” warning.
KEY DISPLAY
CANCEL CANCEL
“Not Enough Disks”
MENU “Language”
– “View
Settings”
ENTER
“System State: Not Enough Disks”
+
“Warning: Firmware Needed”