background image

Hot Pluggable

Hot Pluggable

Hot Pluggable

Hot Pluggable

Hot pluggable technology is designed into drives, fans and redundant power supplies. Hot pluggable
components can be replaced without powering down the storage system or stopping I/O operations.
This feature significantly enhances data availability.

Auto SAS ID Selection

Auto SAS ID Selection

Auto SAS ID Selection

Auto SAS ID Selection

SAS ID is automatically set when a drive is inserted into a drive bay (See drawing on top of unit for bay
numbering).

LED Indicators

LED Indicators

LED Indicators

LED Indicators

Front panel LEDs indicate drive activity, required drive service, and power, giving a quick visual
assessment of overall system storage status.

Rack Density

Rack Density

Rack Density

Rack Density

The MSA50 Enclosure has a 1U height.

Environment Monitoring

Environment Monitoring

Environment Monitoring

Environment Monitoring
Unit (EMU)

Unit (EMU)

Unit (EMU)

Unit (EMU)

Each MSA50 model is equipped with an EMU that constantly monitors the enclosure, the power supplies,
and fans to ensure suggested operating tolerances are maintained.

I/O Module

I/O Module

I/O Module

I/O Module

The single I/O module installed allows one SAS controller to access all drives in the MSA50.

Fault Tolerance

Fault Tolerance

Fault Tolerance

Fault Tolerance

With redundant power supplies and fans, the MSA50 provides a high level of system availability. Using
an internal host based controller, the MSA50 can be configured for RAID levels 0, 1, 1 + 0, 5, 6 (RAID
ADG) when using a HP Smart Array RAID controller.

Manageability

Manageability

Manageability

Manageability

The MSA50 is managed by HP Systems Insight Manager.

Compatibility and

Compatibility and

Compatibility and

Compatibility and
Integration Testing

Integration Testing

Integration Testing

Integration Testing

Intensive compatibility and performance testing with HP ProLiant servers ensures the highest level of
integration available in the industry. For a complete list of supported HP servers and workstations, please
refer to the QuickSpecs and/or User Guide of the array controller or Host Bus adapter that you are
planning to use. The list of supported array controllers and SAS adapters is provided under "Related
Options, Controllers".

Product Kit Contents

Product Kit Contents

Product Kit Contents

Product Kit Contents

Redundant power supplies, single I/O module, 9 drive blanks, warranty card, mounting hardware,
Enclosure user guide, HP SmartStart CD Kit, documentation CD, one 2 Meter SAS external cable and
two Nema 5-15 to C13 and two IEC320-C14 to -C13 power cords.

NOTE: 

NOTE: 

NOTE: 

NOTE: The included SAS cable is only for the P600 controller.
If connecting to a Smart Array P800 or a Smart Array E500 controller one of the following cables must
be ordered:
SAS 4x to Mini SAS 4x 2M – 419571-B21
SAS 4x to Mini SAS 4x 4M – 419572-B21
SAS 4x to Mini SAS 4x 6M – 419573-B21

QuickSpecs

HP 50 Modular Smart Array Enclosure

HP 50 Modular Smart Array Enclosure

HP 50 Modular Smart Array Enclosure

HP 50 Modular Smart Array Enclosure

Product Highlights

DA - 12245   Worldwide — Version 26 — June 8, 2011

Page 4

Summary of Contents for StorageWorks MSA50

Page 1: ...e MSA50 enclosure supports direct attach storage to HP ProLiant and Integrity Servers The MSA50 supports the cascading of shelves in a 1 1 configuration to allow a maximum of 20 SFF drives in a 2U configuration attached to a single controller port This single controller port incorporates four lanes for a total max throughput of 12Gb s for SAS 1 Expansion slot for potential future second I O 6 Powe...

Page 2: ...s and hot plug fans 364430 B21 HP 50 Modular Smart Array Enclosure Japan NOTE NOTE NOTE NOTE Rack mountable 10 SFF drive enclosure with single I O module redundant hot plug power supplies and hot plug fans 364430 291 NOTE NOTE NOTE NOTE For complete compatibility information refer to the Specifications section of this document SAS SATA performance requires a compatible SAS controller This is noted...

Page 3: ...sk drives Provides storage capacity of up to 6 TB SAS per enclosure using 600 GB 6G 10K 2 5 inch SAS dual Port disk drives or 5 TB SAS Midline using 500 GB SAS MDL or 2 5 TB SATA using 250 GB SATA disk drives Cascadable 1 1 for up to 20 spindles in a 2U configuration or 12 TB SAS or 10 TB SAS MDL or 5 TB SATA Modular design allows the MSA50 to be used in any storage configuration from JBOD Just a ...

Page 4: ... can be configured for RAID levels 0 1 1 0 5 6 RAID ADG when using a HP Smart Array RAID controller Manageability Manageability Manageability Manageability The MSA50 is managed by HP Systems Insight Manager Compatibility and Compatibility and Compatibility and Compatibility and Integration Testing Integration Testing Integration Testing Integration Testing Intensive compatibility and performance t...

Page 5: ...are Pack services NOTE NOTE NOTE NOTE The MSA50 has a limited 3 year parts only warranty The SAS drives have a 3 year warranty SAS MDL and SATA drives have a 1 year warranty NOTE NOTE NOTE NOTE Certain restrictions and exclusions apply Hard drive Pre Failure Warranty When used with any one of the Smart Array Family controllers and monitored under HP Systems Insight Manager v4 20 or later HP hard d...

Page 6: ...vices are prepaid For additional HP Care Pack hardware software information as well as orderable part numbers please refer to the URL http www hp com hps carepack Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements from basic to mission critical A full range of HP Care Pack hardware and software services are a...

Page 7: ...ting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Components Components Components Components The following brick level options components do not have individual HP Care Pack Services These items will be included in product HP Care Pack Services into which they are installed Disk Drives Tape Drives CD DVD ROM SCSI Hubs in SBBs Adapte...

Page 8: ...rage Controllers Storage Controllers Storage Controllers Storage Controllers SAS Controller SAS Controller SAS Controller SAS Controller HP Smart Array P800 Controller 512 BBWC Controller 381513 B21 HP Smart Array P600 256 BBWC Controller 337972 B21 Smart Array E500 controller 435129 B21 512MB DDR BBWC Upgrade P600 Controller 372538 B21 NOTE NOTE NOTE NOTE Please see the following Controller Quick...

Page 9: ...D1 Rack Options Rack Options Rack Options Rack Options HP 10642 G2 200mm Extn Shock Rack AF034A HP 10647 G2 200mm Extn Shock Rack AF044A HP 5642 Rack Unassembled 358254 B21 HP S10614 14U Rack Cabinet Shock Pallet 292302 B22 HP 10842 42U Rack Cabinet Pallet 257415 B21 HP 10842 42U Rack Cabinet Shock Pallet 257415 B22 HP 10647 47U Rack Cabinet Pallet 245160 B21 HP 10647 47U Rack Cabinet Crated 24516...

Page 10: ... HA113A1 564 3 Year NBD 9x5 Electronic U8128E 3 Year 4H 13x5 Electronic U8129E 3 Year 4H 24x7 Electronic U8130E 3 Year 6H CTR Electronic U8131E 1 Year NBD 9x5 Electronic U8151E 1 Year 4H 13x5 Electronic U8152E 1 Year 4H 24x7 Electronic U8153E 1 Year 6H CTR Electronic U8154E Installation Electronic U8132E NOTE NOTE NOTE NOTE For additional HP Care Pack hardware software information as well as order...

Page 11: ...n program Datacenter Windows HPC Server 2008 Microsoft Windows Server 2003 R2 Std EE both 32 64 bit Microsoft Windows Server 2003 R2 SBS Microsoft Windows Server 2003 R2 Web Edition Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2003 Enterprise Edition Microsoft Windows Server 2003 on Itanium Novell NetWare 6 5 Open Enterprise Server Red Hat Enterprise Linux 5 x86 AMD 64 E...

Page 12: ...ration Copyright 2011 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors ...

Reviews: