background image

Customer Benefits

Customer Benefits

Customer Benefits

Customer Benefits

Higher Performance per

Higher Performance per

Higher Performance per

Higher Performance per
U of Rack Space

U of Rack Space

U of Rack Space

U of Rack Space

The Serialized nature of SAS combined with the highest spindle count per U
of rack space allows the MSA50 to achieve the greatest I/Os per second
when compared to parallel SCSI.

Price Sensitivity

Price Sensitivity

Price Sensitivity

Price Sensitivity

The MSA50 will be the first SAS/SATA SFF JBOD product that will offer a
level of availability sufficient for the Enterprise and a price structure that is
attractive to SMB.

Investment Protection

Investment Protection

Investment Protection

Investment Protection

The MSA50 allows mix and match SAS or SATA drives within the same
enclosure. Thus making technology transitions simple and cost effective.

Reduced Spares Inventory

Reduced Spares Inventory

Reduced Spares Inventory

Reduced Spares Inventory Universal SFF drives and similar physical characteristics between SAS and

SATA drives allow customers to mix/match SAS and SATA in the same
enclosure and allow the same drives to be used in servers and external
storage.

Key Features

Key Features

Key Features

Key Features

Features of the MSA50 include:

Features of the MSA50 include:

Features of the MSA50 include:

Features of the MSA50 include:

SFF (SAS/SATA) support – Delivering data transfer rates up 3Gb/s for SAS and 1.5Gb/s for SATA

NOTE: 

NOTE: 

NOTE: 

NOTE: SAS/SATA performance requires a compatible SAS controller. This is noted in the product
documentation.

1U rack height.
Supports up to 10 SFF SAS and/or SATA Universal hard disk drives.
Provides storage capacity of up to 6 TB SAS per enclosure (using 600 GB 6G 10K 2.5-inch SAS
dual Port disk drives) or 5 TB SAS Midline (using 500 GB SAS MDL) or 2.5 TB SATA (using 250
GB SATA disk drives)
Cascadable 1+1 for up to 20 spindles in a 2U configuration or 12 TB SAS or 10 TB SAS MDL or
5 TB SATA.
Modular design allows the MSA50 to be used in any storage configuration from JBOD (Just a
Bunch of Disks) to Smart Array storage enclosures.
A common storage platform allows the potential for future storage consolidation to the SAN.
Universal SFF SAS drive carrier - provides better cooling and reliability for by providing increased
air flow through the storage unit.
Hot pluggable disk drives, fans and power supplies.
Field replaceable fans, I/O Module and mid plane.

Easy removal of parts provides better serviceability. No tools are required!

Upgradeability

Upgradeability

Upgradeability

Upgradeability

Potential Upgrade path for a HP MSA50 is as easy as swapping out the I/O Module on the back of the
unit. The unit must be powered down to replace the I/O Module.

Mix and Match of Hard

Mix and Match of Hard

Mix and Match of Hard

Mix and Match of Hard
Drive Types

Drive Types

Drive Types

Drive Types

A benefit of SAS and SATA is the use of a common physical connection which allows for both drive types
to be mixed together on the same backplane. This common backplane allows customers the choice of
using SAS and/or SATA and helps deliver HP's message of industry leading innovation, reliability,
adaptability, and performance by allowing customers to choose the reliability of SAS or the lower cost of
SATA for tiered storage.

QuickSpecs

HP 50 Modular Smart Array Enclosure

HP 50 Modular Smart Array Enclosure

HP 50 Modular Smart Array Enclosure

HP 50 Modular Smart Array Enclosure

Product Highlights

DA - 12245   Worldwide — Version 26 — June 8, 2011

Page 3

Summary of Contents for StorageWorks MSA50

Page 1: ...e MSA50 enclosure supports direct attach storage to HP ProLiant and Integrity Servers The MSA50 supports the cascading of shelves in a 1 1 configuration to allow a maximum of 20 SFF drives in a 2U configuration attached to a single controller port This single controller port incorporates four lanes for a total max throughput of 12Gb s for SAS 1 Expansion slot for potential future second I O 6 Powe...

Page 2: ...s and hot plug fans 364430 B21 HP 50 Modular Smart Array Enclosure Japan NOTE NOTE NOTE NOTE Rack mountable 10 SFF drive enclosure with single I O module redundant hot plug power supplies and hot plug fans 364430 291 NOTE NOTE NOTE NOTE For complete compatibility information refer to the Specifications section of this document SAS SATA performance requires a compatible SAS controller This is noted...

Page 3: ...sk drives Provides storage capacity of up to 6 TB SAS per enclosure using 600 GB 6G 10K 2 5 inch SAS dual Port disk drives or 5 TB SAS Midline using 500 GB SAS MDL or 2 5 TB SATA using 250 GB SATA disk drives Cascadable 1 1 for up to 20 spindles in a 2U configuration or 12 TB SAS or 10 TB SAS MDL or 5 TB SATA Modular design allows the MSA50 to be used in any storage configuration from JBOD Just a ...

Page 4: ... can be configured for RAID levels 0 1 1 0 5 6 RAID ADG when using a HP Smart Array RAID controller Manageability Manageability Manageability Manageability The MSA50 is managed by HP Systems Insight Manager Compatibility and Compatibility and Compatibility and Compatibility and Integration Testing Integration Testing Integration Testing Integration Testing Intensive compatibility and performance t...

Page 5: ...are Pack services NOTE NOTE NOTE NOTE The MSA50 has a limited 3 year parts only warranty The SAS drives have a 3 year warranty SAS MDL and SATA drives have a 1 year warranty NOTE NOTE NOTE NOTE Certain restrictions and exclusions apply Hard drive Pre Failure Warranty When used with any one of the Smart Array Family controllers and monitored under HP Systems Insight Manager v4 20 or later HP hard d...

Page 6: ...vices are prepaid For additional HP Care Pack hardware software information as well as orderable part numbers please refer to the URL http www hp com hps carepack Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements from basic to mission critical A full range of HP Care Pack hardware and software services are a...

Page 7: ...ting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Components Components Components Components The following brick level options components do not have individual HP Care Pack Services These items will be included in product HP Care Pack Services into which they are installed Disk Drives Tape Drives CD DVD ROM SCSI Hubs in SBBs Adapte...

Page 8: ...rage Controllers Storage Controllers Storage Controllers Storage Controllers SAS Controller SAS Controller SAS Controller SAS Controller HP Smart Array P800 Controller 512 BBWC Controller 381513 B21 HP Smart Array P600 256 BBWC Controller 337972 B21 Smart Array E500 controller 435129 B21 512MB DDR BBWC Upgrade P600 Controller 372538 B21 NOTE NOTE NOTE NOTE Please see the following Controller Quick...

Page 9: ...D1 Rack Options Rack Options Rack Options Rack Options HP 10642 G2 200mm Extn Shock Rack AF034A HP 10647 G2 200mm Extn Shock Rack AF044A HP 5642 Rack Unassembled 358254 B21 HP S10614 14U Rack Cabinet Shock Pallet 292302 B22 HP 10842 42U Rack Cabinet Pallet 257415 B21 HP 10842 42U Rack Cabinet Shock Pallet 257415 B22 HP 10647 47U Rack Cabinet Pallet 245160 B21 HP 10647 47U Rack Cabinet Crated 24516...

Page 10: ... HA113A1 564 3 Year NBD 9x5 Electronic U8128E 3 Year 4H 13x5 Electronic U8129E 3 Year 4H 24x7 Electronic U8130E 3 Year 6H CTR Electronic U8131E 1 Year NBD 9x5 Electronic U8151E 1 Year 4H 13x5 Electronic U8152E 1 Year 4H 24x7 Electronic U8153E 1 Year 6H CTR Electronic U8154E Installation Electronic U8132E NOTE NOTE NOTE NOTE For additional HP Care Pack hardware software information as well as order...

Page 11: ...n program Datacenter Windows HPC Server 2008 Microsoft Windows Server 2003 R2 Std EE both 32 64 bit Microsoft Windows Server 2003 R2 SBS Microsoft Windows Server 2003 R2 Web Edition Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2003 Enterprise Edition Microsoft Windows Server 2003 on Itanium Novell NetWare 6 5 Open Enterprise Server Red Hat Enterprise Linux 5 x86 AMD 64 E...

Page 12: ...ration Copyright 2011 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors ...

Reviews: