background image

hp StorageWorks

universal port module kit

installation instructions

Part Number:

 

AA–RSS2B–TE

/958-000281-000

 

 

Second Edition (November 2002)

These installation instructions provide procedures for setting up, 

configuring, and managing a UPM kit in a

n HP

 StorageWorks 

D

irector 2/64 or a 

D

irector 2/140.

Summary of Contents for StorageWorks director 2/140

Page 1: ...tallation instructions Part Number AA RSS2B TE 958 000281 000 Second Edition November 2002 These installation instructions provide procedures for setting up configuring and managing a UPM kit in an HP StorageWorks Director 2 64 or a Director 2 140 ...

Page 2: ...r language without the prior written consent of Hewlett Packard The information contained in this document is subject to change without notice All other product names mentioned herein may be trademarks of their respective companies Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein The information is provided as is without warranty of any ki...

Page 3: ...i Getting Help viii HP Technical Support viii HP Website viii HP Authorized Reseller viii Installation Instructions Supported Kits 1 Installing the UPM 2 Procedural Notes 2 ESD Information 2 Removing the UPM Filler Blank 5 Required Tools 5 Removal 5 Installing the UPM Card 7 Required Tools 7 Installation 8 Miscellaneous Procedures 11 External Loopback Test 11 Unblocking a UPM Card 15 ...

Page 4: ......

Page 5: ...orks director 2 64 or the director 2 140 Document Conventions The conventions included in Table 1 apply Table 1 Document Conventions Element Convention Cross reference links Blue text Figure 1 Key names menu items buttons and dialog box titles Bold File names application names and text emphasis Italics User input command names system responses output and messages Monospace font COMMAND NAMES are u...

Page 6: ...s clarifying information or specific instructions NOTE Text set off in this manner presents commentary sidelights or interesting points of information Symbols on Equipment Any enclosed surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards Enclosed area contains no operator serviceable parts WARNING To reduce the risk of injury from electrical...

Page 7: ...tems Any product or assembly marked with these symbols indicates that the component exceeds the recommended weight for one individual to handle safely WARNING To reduce the risk of personal injury or damage to the equipment observe local occupational health and safety requirements and guidelines for manually handling material Rack Stability WARNING To reduce the risk of personal injury or damage t...

Page 8: ... http thenew hp com country us eng support html Be sure to have the following information available before calling Technical support registration number if applicable Product serial numbers Product model names and numbers Applicable error messages Operating system type and revision level Detailed specific questions HP Website The HP website has the latest information on this product as well as the...

Page 9: ...ith a base configuration of 64 Fibre Channel ports HP also sells optional kits to increase the number of ports to a maximum of 64 for the Director 2 64 and a maximum of 140 for the Director 2 140 Use the procedures described in this chapter for the following director UPM kits 8 Port UPM Kit 300833 B21 A6574B 2 Short wave 4 Port cards includes 8 short wave 2 Gbps SFP optical transceivers 1 Loop bac...

Page 10: ...g procedure and continue to the next step of that procedure ESD Information When performing procedures described in this section follow all ESD procedures WARNING statements and CAUTION statements When installing UPMs always connect a grounding cable to the director chassis and wear an ESD wrist strap CAUTION To avoid causing machine errors or damage while working on the director follow ESD proced...

Page 11: ...Director 2 64 rotate the cable management assembly if used to reach the grounding point The assembly locks into the raised position Any cables attached to the Director 2 64 are then held up allowing access to the lower front of the chassis If no cables are attached to the director the assembly may be removed Figure 1 Director 2 64 ESD grounding point front 1 Director 2 64 ESD Grounding Point PWR O...

Page 12: ... ESD grounding points As shown in Figure 2 the ESD grounding point for the rear of the Director 2 140 chassis is located next to the maintenance port As shown in Figure 3 the ESD grounding point for the rear of the Director 2 64 chassis is located at the bottom center directly below the maintenance port ...

Page 13: ... required tools is provided Required Tools The torque tool and hex adapter provided with the director are required to perform the installation procedures Removal To remove a filler blank 1 Unlock and open the cabinet front door if the director is rack mounted and installed in a custom equipment cabinet If the director is installed in a stand alone configuration go to step 2 2 Identify the filler b...

Page 14: ...the torque tool into each locking Allen screw as shown in Figure 4 for the Director 2 64 and Figure 5 for the Director 2 140 Turn each screw counter clockwise until the spring releases and the tool turns freely Figure 4 Director 2 64 UPM filler blank removal 1 UPM Filler Blank 2 Torque Tool ...

Page 15: ...ve it from the director chassis Installing the UPM Card Use the following procedures to install a UPM card A list of required tools is provided Required Tools The following tools are required to perform these procedures ESD grounding cable and wrist strap Torque tool and hex adapter provided with the director Fiber optic protective plugs provided with the director ...

Page 16: ...or follow ESD procedures by connecting a grounding cable to the director chassis and wearing an ESD wrist strap CAUTION Ensure that protective plugs are inserted into the UPM card optical transceiver receptacles This prevents damage to sensitive components and prevents injury to the eye if the laser is viewed directly Figure 6 Director 2 64 UPM card installation 1 UPM Card 2 Torque Tool SHR 2302 S...

Page 17: ...its stiffener and insert it in the chassis card track as shown in Figure 6 for the Director 2 64 and Figure 7 for the Director 2 140 The yellow locking Allen screw should be at the bottom for the Director 2 64 and it should align with the yellow lock symbols on the frame for the Director 2 140 Verify the card is aligned in the card tracks then slide it forward until it makes contact with the backp...

Page 18: ...ont of the card cage and even with other director logic cards 5 Perform an external loopback test for all ports on the replacement UPM card For instructions refer to External Loopback Test and return here If the test fails see the Maintenance Analysis Procedures MAP in the Diagnostics chapter of the hp StorageWorks director 2 64 service manual to isolate the problem 6 Disconnect the ESD wrist stra...

Page 19: ... UPM Card of the hp StorageWorks director 2 64 service manual A6534 96022 AA RS2EA TE Miscellaneous Procedures The following are miscellaneous procedures that you can perform on your UPM card External Loopback Test To perform an external loopback test for a single port or a UPM card four ports 1 If the UPM card is currently being used in a fabric then notify storage users on the fabric that a disr...

Page 20: ...s b At the Port Card View right click the tested port A menu displays c Choose Reset Port A Reset Port n message box displays where n is the port number d Click OK The port resets e Click Back To Full View to return to the Hardware View 6 Disconnect the fiber optic jumper cable from the port to be tested If a UPM card will be tested disconnect all four fiber optic jumper cables IMPORTANT If name s...

Page 21: ...lect a UPM card for test type the port number of any of the four ports an the card in the Port Number field then choose All Ports On Card 10 At the Diagnostics Test list box choose External Loopback 11 Click Next Beaconing initiates for the port or UPM card selected for test At the Hardware View a yellow triangle displays at the top of the UPM card At the Port Diagnostics dialog box the following ...

Page 22: ...hes beacons and the green LED illuminates indicating loopback traffic through the port NOTE Click Stop Test at any time to abort the loopback test 15 When the test completes test results display for each port tested as Port xx Passed or Port xx Failed in the message area of the dialog box If a port fails the test the amber LED for the port remains illuminated 16 When finished click Cancel to close...

Page 23: ... and right click the mouse to open a list of menu options 5 Choose Unblock All Ports option The Unblock All Ports dialog box displays as shown in Figure 9 Figure 9 Unblock All Ports dialog box 6 Click Yes The following occurs to indicate the UPM card is unblocked and the attached devices are online Emulated green LEDs associated with all four ports illuminate at the Port Card View Green LEDs assoc...

Page 24: ......

Reviews: