background image

QuickSpecs 

hp

 AlphaServer

 SC20

 

DA-10976 

North America — Version 1 —  May 24, 2002

 

22

 

Options

 

Step 10 – Hardware and Software Supplemental Support Services 

(continued) 

AlphaServer SC SBB Services 

For each AlphaServer SBB selected in Step 5, select an AlphaServer SC SBB service part number based on the hours of service coverage desired. 
 

3-year SBB 5X9/4 HR 

FP-CS114-36

 

3-year SBB 7X24 HR 

FP-CS214-36

 

 

AlphaServer SC MBB Services 

For each AlphaServer MBB selected in Step 4, select appropriate DS20E or DS10 Priority Service part number. 

 

 

DS20E 3-year Priority Service 9x5/4 HR 

FP-A01MA-36

 

DS20E 3-year Priority 24 Service 24x7/4 HR 

FP-A02MA-36

 

DS10 3-year Priority Service 9x5/4 HR 

FP-A01BA-36

 

DS10 3-year Priority 24 Service 24x7/4 HR 

FP-A02BA-36

 

 

AlphaServer SC Software Services 

 

AlphaServer SC System 1-Node License Subscription Service 

QT-6EQAA-TA

 

AlphaServer SC System 16-Node License Subscription Service 

QT-6EQAA-TB

 

AlphaServer SC System 32-Node License Subscription Service 

QT-6EQAA-TC

 

AlphaServer SC System 64-Node License Subscription Service 

QT-6EQAA-TD

 

AlphaServer SC System 128-Node License Subscription Service 

QT-6EQAA-TE

 

AlphaServer SC Software Update Media & Doc Distribution 

QT-6EQAA-E8

 

AlphaServer SC Software Update Documentation Distribution 

QT-6EQAA-KZ

 

 

Priority Service Plan for Layered Products

*

 

 

AlphaServer SC Layered Product Support for up to 1 Node 

FP-S1207-36

 

AlphaServer SC Layered Product Support for up to 4 Nodes 

FP-S1215-36

 

AlphaServer SC Layered Product Support for up to 16 Nodes 

FP-21221-36

 

AlphaServer SC Layered Product Support for up to 32 Nodes 

FP-21228-36

 

AlphaServer SC Layered Product Support for up to 64 Nodes 

FP-21233-36

 

AlphaServer SC Layered Product Support for up to 128 Nodes 

FP-21233-36

 

NOTE:  *These part numbers reflect the most commonly purchased AlphaServer SC 

configurations, and are not inclusive of any other software layered products. 

Please refer to the Priority Service Plan for Layered Products, One-Step 

Quoting Table, for additional ordering information.

 

 

Software Support Menu 5/List 3 

QR-SMSW3-A

*

 

 

Hardware and Software Supplemental Support Services – Europe Only 

 

In EMEA the corporate Service Menu (release 3b) is used and any service from Installation, Hardware Maintenance Service, Software Support, 

9 x 5 up to 24 x 7 can be offered to the Customer. 

 

To Administrate and Quote the Customer service offer, the Building Block part numbers and any optional products as mentioned in the above 

steps needs to be entered. The NCAS system will automatically recognize the Compute Building Block containing the 4 or 32 systems or the 

Base Building Block and reflects the bundled price. 

 

When the Customer requires both hardware maintenance and software support a DSS service level should be selected, which still leaves the 

flexibility to have a hardware coverage level of C or D and a higher software level of A or B as example. 

Summary of Contents for SC20

Page 1: ... 4 MB cache each One AlphaServer SC Elan adapter card Tru64 UNIX Some SC40 SC45 CBBs can be added for mixed configurations Interconnect Building Block IBB IBB includes a multi port switch using technology from Quadrics Supercomputers World as well as a Management Network and console network components Management Building Block MBB consists of one Management Server based on a DS20E or DS10 and also...

Page 2: ...ithin each domain all nodes should be of the same type It is recommended that the Compute Serving Domains be configured with the maximum possible number of nodes since later expansions would require rewiring as well as rebuilding of the file systems for the domains AlphaServer SC System Software supports up to four Compute Serving Domains For each compute server domain CFS storage is included for ...

Page 3: ...select one to 27 units to complement CBB cabinets In a 32 node CBB four BBBs may be added In a 4 node CBB 27 BBBs may be added 31 nodes AlphaServer SC20 68 833 Base Building Block DA 81BAA AL Each AlphaServer SC20 68 833 CBB includes the following Four or 32 AlphaServer SC20 68 833 Base Building Blocks One H9B15 2 m tall carbon black rack assembly with AlphaServer SC door and PDUs without side pan...

Page 4: ... four SC40 or SC45 BBBs This is the only way to configure DS20L and ES40 or ES45 in the same cabinet AlphaServer ES40 or ES45 nodes will be configured in one or two Domains File Serving and or Compute Domains Rules in the preface apply Step 2a Optional Select the number of AlphaServer SC40 SC45 CBBs AlphaServer SC40 CBB is a hardware rack with four specially configured ES40 nodes Select from one m...

Page 5: ...lding Blocks Select one to three SC45 BBBs if one CBB 1 has been selected in Step 2a AlphaServer SC45 68 1000 Base Building Block DA 68DBA AL Each AlphaServer SC45 68 1000 CBB includes the following items One AlphaServer SC45 68 1000 Base Building Blocks in CBB 1 or five AlphaServer SC45 68 1000 Base Building Blocks in CBB 5 One H9B15 ST SU 2 m tall rack assembly with AlphaServer SC door without s...

Page 6: ... 1024 MB DIMMs provides 16 GB per node MS610 FA For ES45 To achieve 4 way memory interleaving with room for memory expansion in each node select a memory option from the following list and order at least four memory options for each ES45 node in the system 512 MB memory option 4 x 128 MB DIMMs provides 2 GB per node MS620 AA 1 GB memory option 4 x 256 MB DIMMs provides 4 GB per node MS620 BA 2 GB ...

Page 7: ...ing integration and full test of the IBB the CBBs the SBB s and the MBB Installation and basic configuration of system software and storage Customer Services installation on site Step 3b Select the 128 way IBB 16 port switch cards and cables If the AlphaServer SC20 system is larger than 16 nodes or is expected to become larger than 16 nodes choose one of the following parts AlphaServer SC 128 way ...

Page 8: ...e IBB the CBBs the SBB s and the MBB Installation and basic configuration of system software and storage Customer Services installation on site Step 4 Select Management Building Block MBB and Options for Console and Management Expansion Step 4a Mandatory Select a Management Server An AlphaServer SC MBB is specially configured for the management of an AlphaServer SC system It is mandatory that a MB...

Page 9: ...al full or partial set of 32 nodes order one each of the following AlphaServer SC 32 port console network upgrade 3X SCNTA KC Ethernet Cable 1 meter 8MP X 8MP BN25G 01 Power cord for rack mounting of DECserver 732 BN35S 02 The AlphaServer SC 128 way IBB has Management Ethernet support for the first 40 of the nodes configured as described in Step 1 and 2 For one additional full or partial set of 48...

Page 10: ...yboard and track ball 3R A3498 AA One 3U 30 inch deep extension rail for the monitor 2T QH915 03 One Tabletop Console IBB 128 supports one monitor and one keyboard switched between nodes 0 and 1 IBB 16 supports one monitor and one keyboard directly attached to the management node This monitor requires a video cable for connection to the console switch Select one monitor one monitor power cord one ...

Page 11: ...e Grille pitch VGA to 1792 x 1344 85Hz Dual Video Input USB Hub MPRII TCO 99 Energy Star Compliant Northern Hemisphere with NA Power Cord VGA Cable 3R A3398 AA Same as above with Euro Power Cord 3R A3399 AA Same as above APD no Power Cord 3R A3400 AA Same as above PRC with Power Cord CCIB 3R A3401 AA Same as above Southern Hemisphere with Australia New Zealand Power Cord 3R A3402 AA Monitor Power ...

Page 12: ... AC Cyrillic keyboard Russian 3R LKQ48 BT Czech keyboard 3R LKQ48 BV Danish keyboard 3R LKQ48 AD Dutch keyboard 3R LKQ48 AH Finnish keyboard 3R LKQ48 AF French keyboard 3R LKQ48 AP German keyboard 3R LKQ48 AG Greek keyboard 3R LKQ48 BH Hebrew keyboard 3R LKQ48 AT Hungarian keyboard 3R LKQ48 BQ International keyboard 3R LKQ48 BA Italian keyboard 3R LKQ48 AI Japanese keyboard 3R LKQ48 AJ Korean keyb...

Page 13: ...SCFCA AA 3X SCFDA AA to the included host adapters and to the hierarchical storage dual controller shelf DA SCDMA HA BA Each Fibre Channel Switch is packaged with a rack mount kit and appropriate power cord Optional storage configurations can be added to provide extra user RAID storage Various amounts of redundancy can also be configured The storage and cabinetry components for these can be found ...

Page 14: ...10K rpm Ultra3 SCSI Universal Hot Plug HDD 1 inch height 3R A0585 AA 36 4 GB 10K rpm Ultra3 SCSI Universal Hot Plug HDD 1 inch height 3R A0919 AA 72 GB 10K rpm Ultra3 SCSI Universal Hot Plug HDD 1 inch height 3R A3050 AA 18 2 GB 15K rpm Ultra3 SCSI Universal Hot Plug HDD 1 inch height 3R A1543 AA 36 GB 15K rpm Ultra3 SCSI Universal Hot Plug HDD 1 inch height 3R A3079 AA Step 5c Mandatory Select si...

Page 15: ...grade GBIC 3X SCFGA AA 2 64 bit PCI to Fibre Channel HBA ES40 only DS KGPSA CA 2 2 2 2 Fiber optic Cable 50 125 xx 2 5 15 30 50 BNGBX xx 2 2 2 2 Ethernet Cable connects Fibre Channel Switch es to management network BN25G 03 1 Step 5e Mandatory Select extra AdvFS Utilities licenses Select extra licenses for installation on the system storage nodes of the Compute Serving Domains Number of Domains 1 ...

Page 16: ... BB Cable for 10BaseT Twisted Pair connection xx length in meters BN25G xx PCI Gigabit Ethernet adapter UTP FE Ethernet adapter Twisted Pair 1 2 DEGPA TA PCI Gigabit Ethernet adapter SC connectors MMF no boot support 1 2 DEGPA SA SC SC dual Fibre Optic cable mm pp xx length in meters BN34B xx ATM Each adapter controller uses one PCI slot First two DS20L nodes in each domain have their PCI slots po...

Page 17: ...d storage Your Account Manager will quote for any additional integration services required for the assembly of additional equipment included desired third party options or racks Compaq staff may consult documents EK MARQE CN B IB H9A15 3 DBM and B IC H9A15 3 DBM for cabinet enclosure rules for M Series enclosures Step 9 Mandatory System Software and Documentation The following software and documen...

Page 18: ...nt Software Media and Documentation Choose a combination of licenses that match or exceed the number of nodes in the AlphaServer SC20 As an example a system with 48 DS20L nodes and 4 ES40 nodes can be licensed for AlphaServer Development Software by combining one 16 node license QM 6ERAA AB and one 32 node license QM 6ERAA AC with four 1 node licenses QM 6ERAA AA AlphaServer SC Development Softwar...

Page 19: ...m Packages that meet a full range of customer support requirements Program Features Principal Server Priority 9 x 5 HW SW support 4 hour response on site hardware support 2 hour response for Bronze software support License Subscription for Compaq O S software and embedded L P unlimited users and server extensions for Tru64 UNIX Condist update distribution for Tru64 UNIX and layered products Layere...

Page 20: ...ty Gold Executive HW Support at same level as corresponding package for Principal server License Subscription Compaq O S Telephone support through Principal server covered by full support package Program Features Installation Installation is included for all AlphaServer SC20 building blocks Pre installation review Basic product usage info Unpacking of equipment No software installation added Assem...

Page 21: ...umbers listed in the CarePaq Priority Service section are CarePaq service prices for single ES40 45 units Priority service for the Principal and Subsequent servers will provide hardware support for options internal to CBB s remedial software support and advisory and rights to new versions on the CBB s including Tru64 UNIX Base unlimited users and Server Extensions and Open Source Internet Software...

Page 22: ... Product Support for up to 1 Node FP S1207 36 AlphaServer SC Layered Product Support for up to 4 Nodes FP S1215 36 AlphaServer SC Layered Product Support for up to 16 Nodes FP 21221 36 AlphaServer SC Layered Product Support for up to 32 Nodes FP 21228 36 AlphaServer SC Layered Product Support for up to 64 Nodes FP 21233 36 AlphaServer SC Layered Product Support for up to 128 Nodes FP 21233 36 NOTE...

Page 23: ...n site consulting QS A1758 HL Basic Systems Installation and Administrative Service 30 days on site consulting QS A1759 HL Initial Systems Installation and Administrative Service 10 days on site consulting QS A1760 HL Standard Applications Migration and Optimization Service 60 days on site consulting QS A1758 HL Basic Systems Installation and Administrative Service 30 days on site consulting QS A1...

Page 24: ...1 F to 122 F 5 C to 50 C Storage 60 days 40 F to 151 F 40 C to 66 C Rate of change 20 F hr 11 C hr NOTE Maximum operating temperature at sea level reduce by 1 8 F 1 C for each 2 000 ft 600 m above sea level Relative Humidity Operating 20 to 80 Non operating 20 to 80 Storage 60 days 10 to 95 Rate of change 20 hr Operating 82 F 28 C Maximum Wet Bulb Temperature Storage 60 days 115 F 46 C Maximum Dew...

Page 25: ...wer cord 16 A Power Cords Rack AC Inlet 3M 10 ft 10 per Power Distribution Unit 2 per U possible NEMA L6 20 North America or IEC 320 C14 other countries Number of Power Cords DA SCAPA AA AB 6 DA SCAPB AA AB 6 Dimensions H x W x D 1 75 x 17 5 x 20 5 in 4 5 x 44 5 x 52 cm fits 1 75 in 1U standard RETMA cabinet AS SC20 Base Building Block Rackmount Node System Drawer Part Number DA 81BAA AL Shipping ...

Page 26: ...6 36 0 ENVIRONMENTAL Temperature Operating Rackmount 50 F to 95 F 10 C to 35 C Non operating 40 F to 151 F 40 C to 66 C Storage 60 days 40 F to 151 F 40 C to 66 C Rate of change 20 F hr 11 C hr NOTE Maximum operating temperature at sea level reduce by 1 8 F 1 C for each 2 000 ft 600 m above sea level Relative Humidity Operating 20 to 80 Non operating 20 to 80 Storage 60 days 10 to 95 Rate of chang...

Page 27: ...30 1 in 35 2 x 44 7 x 76 5 cm fits 14 in 8U standard RETMA cabinet Shipping Dimensions 28 8 x 24 x 40 in 73 2 x 60 7 x 101 6 cm AS SC45 40 Base Building Block Rackmount Node System Drawer Part Number DA 64CBA AL Part Number DA 68DBA AL Weight When lifting Nominal 110 lb 50 kg Maximum 167 2 lb 76 kg Nominal 130 lb 59 kg Total added to cabinet brackets slides cables Maximum 202 4 lb 92 kg Shipping W...

Page 28: ... 2 Drawer Rackmount Dimensions H x W x D 17 75 x 18 0 x 26 in 44 45 x 46 0 x 66 0 cm fits 22 75 in 10U standard RETMA cabinet Part Number DA SCDMA AA Shipping Dimensions Mounted in Cabinet Weight Nominal 73 lb 33 kg When lifting heaviest individual component Maximum 73 lb 33 kg Nominal 210 lb 95 5 kg Total added to cabinet brackets slides cables Maximum 210 lb 95 5 kg Shipping Weight Nominal 310 l...

Page 29: ... 295 kg 1022 lb 465 kg Maximum 1210 lb 550 kg 1378 lb 626 kg Clearances Operating See specific cabinet requirements See specific cabinet requirements Service 36F 36B 0Side 36 36 0 ENVIRONMENTAL Temperature Operating Rackmount 50 F to 95 F 10 C to 35 C Non operating 40 F to 151 F 40 C to 66 C Storage 60 days 40 F to 151 F 40 C to 66 C Rate of change 20 F hr 11 C hr NOTE Maximum operating temperatur...

Page 30: ...1 03 Grms 5 300 Hz ELECTRICAL Power supplies are universal PFC auto ranging 100 240 VAC Nominal Voltage VAC 200 to 240 Voltage Range VAC temporary condition 180 to 250 Power Source Phase Single Nominal Frequency Hz 50 60 Frequency Range Hz 49 to 51 59 to 61 RMS Current maximum steady state Each power cord 16 A Power Cords Agency Approvals Series EA2008 UL Listed to UL1950 third edition UL CNL Cert...

Page 31: ...MS StorageWorks Tru64 and TruCluster are registered trademarks or trademarks of Compaq Information Technologies Group L P in the U S and or other countries UNIX is a trademark of The Open Group in the U S and or other countries All other product names mentioned herein may be trademarks or registered trademarks of their respective companies Compaq shall not be liable for technical or editorial erro...