Component identification 62
Position
Default
Function
S10
—
Reserved
S11
—
Reserved
S12
—
Reserved
To access the redundant ROM, set S1, S5, and S6 to On.
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase
all system configuration settings from both CMOS and NVRAM.
CAUTION:
Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
properly configure the server or data loss could occur.
Drive numbering
Depending on the server configuration, the drive bay numbering for the server varies. For more
information, see the section that represents your server configuration:
•
Hot-plug drive numbering (single 12G drive backplane)
•
Hot-plug drive numbering (dual 6G drive backplanes)
•
Non-hot-plug drive numbering
Hot-plug drive numbering (single 12G drive backplane)
Item Description
1
Drive bay 1
2
Drive bay 2