Removal and replacement procedures 52
To install the QPI mezzanine assembly
:
1.
Align the interposer riser card of QPI mezzanine assembly to the system board QPI mezzanine connector.
2.
Install QPI mezzanine assembly to the tray and fasten the screws.
Figure 34
Installing the QPI mezzanine assembly
System battery
The server uses nonvolatile memory that requires one battery per system board to retain system
information when power is removed.
This 3-volt lithium coin cell battery is located on the system board.
Figure 35
System battery location
WARNING:
Note the following reminders when replacing the system battery:
•
Replace the battery with the same type as the battery recommended by HP. Use of another battery may
present a risk of fire or explosion.
•
A risk of fire and chemical burn exists if the battery is not handled properly. Do not disassemble, crush,
puncture, or short external contacts, or expose the battery to temperatures higher than 60°C (140°F).