Diagnostic tools and setup utilities 76
Table 11
POST error messages
Error code
Error message
Description/corrective action
650h
System Fan 1a Missing
If system fan1a is not installed or
has failed, when the system is
installed with non-redundant fans,
this message appears and the
system shuts down in minutes.
When the system is installed with
redundant fans, if only one fan is
missing, this appears and the other
fans run at high speed. If two fans
are missing, this appears and the
system shuts down in minutes.
651h
System Fan 1b Missing
If system fan1b is not installed or
failed, when one fan missing, this
message appears and other fans
run at high speed. When two fans
missing at the same time, this
appears and system shuts down in
minutes.
652h
System Fan 2a Missing
If system fan2a is not installed or
failed, when the system installed
non-redundant fan, this message
appears and the system shuts down
in minutes. When system installed
with redundant fan, if only one fan
missing, this appears and the other
fans run at high speed. If two fans
missing, this appears and system
shuts down in minutes.
653h
System Fan 2b Missing
If system fan2b is not installed or
failed, when one fan missing, this
message appears and other fans
run at high speed. When two fans
missing at the same time, this
appears and system shuts down in
minutes.
654h
System Fan 3a Missing
If system fan3a is not installed or
failed, when the system installed
non-redundant fan, this message
appears and system shuts down in
minutes. When system installed with
redundant fan, if only one fan
missing, this appears and the other
fans run at high speed. If two fans
missing, this appears and system
shuts down in minutes.