Removal and replacement procedures 58
Onboard low-profile PCI expansion slot cover
CAUTION:
To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Remove the access panel ("
" on page
5.
Remove the onboard PCI expansion slot cover.
To replace the component, reverse the removal procedure.
Primary PCI riser cage
The primary PCIe riser location in this server supports either a GPU riser cage or a two-slot PCI riser cage.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.