Hardware options installation 47
Fan population guidelines
Configuration Fan bay
1
Fan bay
2
Fan bay
3
Fan bay
4
Fan bay
5
Fan bay
6
One processor,
non-redundant
Fan
Fan
Blank
Fan
Blank
Blank
One processor,
redundant
Fan
Fan
Fan
Fan
Fan
Blank
Two processors,
non-redundant
Fan
Fan
Blank
Fan
Blank
Fan
Two processors,
redundant
Fan
Fan
Fan
Fan
Fan
Fan
•
In the redundant fan mode:
o
If one fan rotor fails, the system continues to operate without redundancy. This condition is
indicated by a flashing amber Health LED.
o
If two fan rotors fail, the operating system shuts down.
Installing a hot-swap fan module
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To install the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Remove the access panel (on page
5.
Summary of Contents for ProLiant DL60 Gen9
Page 14: ...Component identification 14 Fan locations ...
Page 22: ...Operations 22 o Secondary PCI riser cage o PCI blank ...
Page 86: ...Cabling 86 FBWC module slot 1 cabling FBWC module slot 2 cabling ...
Page 87: ...Cabling 87 FBWC module slot 3 cabling Smart Storage battery cabling ...
Page 117: ...Support and other resources 117 ...
Page 118: ...Support and other resources 118 ...