Component identification 89
Front panel LED power fault codes
The following table provides a list of power fault codes, and the subsystems that are affected. Not all
power faults are used by all servers.
Subsystem
Front panel LED
behavior
System board
1 flash
Processor
2 flashes
Memory
3 flashes
Riser board PCIe slots
4 flashes
FlexibleLOM
5 flashes
Removable HPE Flexible Smart Array
controller/Smart SAS HBA controller
6 flashes
System board PCIe slots
7 flashes
Power backplane or storage backplane
8 flashes
Power supply
9 flashes
For more information, see "Front panel LEDs and buttons (on page
)."
Rear panel components
Item
Description
1
Slot 3 PCIe3 x8 (8, 4, 1)
2
Slot 2 PCIe3 x8 (8, 4, 1)
3
Slot 1 PCIe3 x16 (16, 8, 4, 1)
4
Non-hot-plug power supply
5
Power supply blank (bay 2 of optional redundant power
supply module)
6
Hot-plug power supply (bay 1 of optional redundant
power supply module)
7
NIC connector 2
8
NIC connector 1/iLO connector
9
Video connector
10
USB 3.0 connectors
Summary of Contents for ProLiant DL60 Gen9