Component identification 97
•
4LFF device bay numbering
Hot-plug drive LED definitions
Item LED
Status
Definition
1
Locate
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an
update.
2
Activity ring
Rotating green Drive activity
Off
No drive activity
3
Do not remove Solid white
Do not remove the drive. Removing the drive causes one or
more of the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green The drive is rebuilding or performing a RAID migration, strip size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
Summary of Contents for ProLiant DL380 Gen9
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 26: ...Illustrated parts catalog 26 ...
Page 106: ...Cabling 106 o Connect to a PCI expansion board ...
Page 107: ...Cabling 107 o Connect to an HPE 12G SAS Expander Card Bay 2 installation ...
Page 112: ...Cabling 112 Drive bay 1 is empty Connect using the NVMe power cable 776392 001 ...
Page 129: ...Cabling 129 x4 SATA connector Connect the 2 SFF drive bay power cable ...