System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (HxWxD)
(with feet/bezel)
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Weight
Weight
Weight
Weight(approximate)
Maximum
60 lb (27.22 kg)
No drives:
47.18 lb (20.41 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Input Voltage
100-132 VAC, 200-240 VAC
Rated Input Current
7.5A (100VAC), 3.8A (200VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
735 W
BTU Rating
BTU Rating
BTU Rating
BTU Rating
2508 BTU/HR
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/powercalcs.asp
.
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL380 G4
- Click on: "Power Calculator" link. (You may need to scroll down to see it.)
SCSI Connectors
SCSI Connectors
SCSI Connectors
SCSI Connectors
One external VHDCI connector
NOTE:
NOTE:
NOTE:
NOTE: External VHDCI not included on SAS Models
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
(per power supply)
Rated Steady-State Power 575W
Maximum Peak Power
575W
Temperature Range
Temperature Range
Temperature Range
Temperature Range
NOTE:
NOTE:
NOTE:
NOTE: All temperature
ratings shown are for sea
level. An altitude derating
of 1 C° per 300 m (1.8 FR
per 1000 ft) to 3048 m
(10,000 ft) is applicable.
No direct sunlight allowed.
Operating
50° to 95° F (10° to 35° C)
Shipping
-40° to 158° F (-40° to 70° C)
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Temperature
Temperature
Temperature
Temperature
82.4° F (28° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
NOTE:
NOTE:
NOTE:
NOTE: Storage maximum
humidity of 95% is based
on a maximum
temperature of 45°C
(113°F). Altitude maximum
for storage corresponds to
a pressure minimum of 70
kPa.
Operating
10% to 90%
Shipping
5% to 95%
QuickSpecs
HP ProLiant DL380 Generation 4 (G4)
HP ProLiant DL380 Generation 4 (G4)
HP ProLiant DL380 Generation 4 (G4)
HP ProLiant DL380 Generation 4 (G4)
Technical Specifications
DA - 12028 Worldwide — Version 58 — February 12, 2007