utility.
Power Supply
HP has a new design for ProLiant power supplies - the new Common Slot power supply bay. This design
provides the customer with commonality in power supplies across multiple platforms to save on the cost
of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant
Servers come with high-efficiency Common Slot power supplies. The new HP Common Slot power supplies
are designed for the highest power efficiency without degrading performance of the ProLiant server.
These power supplies have efficiency ratings up to 94%. There are multiple power supply options available
allowing you to "right-size" the most appropriate power supply for your server configuration. To make
sure you select the correct power supply to meet your configuration, please use the HP Power Advisor at:
www.hp.com/go/hppoweradvisor
. All HP Common Slot power sources are UL, CE mark compliant, hot-
plug, and support Redundant Power Management: In addition to the shared power and cooling
infrastructure, the DL2000 contains advanced power metering and power capping technologies. The
Power Interface Controller allows you to configure the system for full AC redundancy or AC redundancy
with power throttling, depending on your configuration. With the optional Dynamic Power Capping mode,
the DL2000 can boost the capacity of your data center by reclaiming trapped power and cooling capacity.
HP offers several Common Slot Power Supply Options for this platform.
NOTE:
The 80 PLUS program is a unique forum that unites electric utilities, the computer industry, and
consumers in an effort to bring energy efficient technology solutions to the marketplace. 80 Plus
independently tests power supply efficiency and publicly posts the results on 80Plus.org.
Optional power supplies can be purchased through power supply option kits (see Power Supply Options for
part numbers).
NOTE:
Mixing of power supplies in the same chassis is not supported. All power supplies must be of the
same type, all, 750W 94%, all 1200W 94%, or all 1200W 90%. If non-matched power supplies are inserted
you will get errors and operation will fail.
System Fans
4 x 80mm system fans ship standard; Non-hot plug, Non-redundant.
Required Cabling
For required cabling information, refer to the HP Web site at:
www.hp.com/servers/dl170e
.
Operating Systems and
Virtualization Software
Support for ProLiant
Servers
Microsoft Windows Server
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Oracle Solaris
VMware ESX
Citrix XenServer
NOTE:
For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization
Software and latest listing of software drivers available for your server including how to purchase from
HP, please visit our OS Support Matrix Site at:
http://www.hp.com/go/ossupport
QuickSpecs
HP ProLiant DL2000 Multi Node Server
Standard Features
DA - 13847 North America — Version 31 — December 13, 2013