Specifications

H: 4.2 cm (1.64 inch), W: 44.3 cm (17.42 inch), D: 39 cm (15.4 inch)

Dimensions

6.1 kg (13.45 lb)

Weight

100–127/200–240 volts

AC voltage

1

2 A/1 A

Maximum current

50/60 Hz

Frequency range

Operating: 5°C to 40°C (41°F to 122°F), Non-operating: -40°C to 65°C (-40°F to 149°F)

Temperature

Operating: 15% to 80% at 40°C (104°F), Non-operating: 20% to 90% at 65°C (149°F)

Relative humidity

nl

(non-condensing)

Operating: 2 km (6,500 ft), Non-operating: 4.6 km (15,000 ft)

Maximum altitude

Noise Emission LwA=52 dB at virtual work space according to DIN 45635 T.19

Acoustic

The 10/100/1000 Mbps RJ-45 twisted-pair ports are compatible with IEEE 802.3ab 1000Base-T,
IEEE 802.3u 100Base-TX, and IEEE 802.3 10Base-T standards.

Connectors

Complies with EN60950-1/IEC 60950-1, CSA 22.2 No. 60950-1, and UL 60950-1 standards.

Safety

1

The controller automatically adjusts to any voltage between 100–127 and 200–240 volts at either 50 or 60 Hz.

Summary of Contents for ProCurve MSM760

Page 1: ...d Locator LEDs 6 USB port not used 2 Ethernet Ports 1 Internet 2 LAN 7 Ethernet LEDs 3 Console port 4 LCD display Package contents Controller console cable two mounting brackets eight 8 mm screws four 5 8 inch screws four rubber feet power cord and documentation LCD display The LCD displays the following The controller type either Mobility Controller or Access Controller The maximum number of supp...

Page 2: ...ndition persists contact technical support Flashing The controller is fully operational On The normal state it indicates that there are no fault conditions on the controller Off Fault orange A fault has occurred on the controller Flashing On briefly at the beginning of the self test after the controller is powered on or reset If it remains on the controller has encountered a fatal hardware failure...

Page 3: ...es not overload the power circuits wiring and over current protection To determine the power supply circuit load add the ampere ratings of all devices installed on the circuit including the controller and compare the total with the rating limit for the circuit The maximum ampere ratings are typically printed on the devices near the AC power connectors Do not install the controller in an environmen...

Page 4: ...EIA TIA rack Installing the controller After determining the configuration and preparing the site mount the controller in a stable location The controller can be installed in a rack or cabinet or placed on a table or shelf Mounting the controller in a rack or cabinet The controller can be mounted in any EIA standard 19 inch telco rack or communication equipment cabinet IMPORTANT Equipment Cabinet ...

Page 5: ...n reconnecting the power cord or by using its management tool Resetting to factory defaults HP recommends that you use the controller web interface to reset the controller to factory defaults as described in the HP MSM760 Controllers Installation Guide Support and other resources For worldwide technical support information see the HP support website at www hp com support The HP MSM7xx Controllers ...

Page 6: ...December Дата изготовления Дата изготовления включена в серийный номер изделия CCYMPPPZZZ формат серийного номера HP для данного изделия Дата изготовления указана как YM в серийном номере где Y соответствует году с началом отсчета в каждом новом десятилетии начиная с 2010 а M соответствует месяцу изготовления устройства Например в обозначении 3A цифра 3 соответствует 2013 году а A обозначает ноябр...

Page 7: ...F Relative humidity nl non condensing Operating 2 km 6 500 ft Non operating 4 6 km 15 000 ft Maximum altitude Noise Emission LwA 52 dB at virtual work space according to DIN 45635 T 19 Acoustic The 10 100 1000 Mbps RJ 45 twisted pair ports are compatible with IEEE 802 3ab 1000Base T IEEE 802 3u 100Base TX and IEEE 802 3 10Base T standards Connectors Complies with EN60950 1 IEC 60950 1 CSA 22 2 No ...