B-5
Switch Ports and Network Cables
Twisted-Pair Cable/Connector Pin-Outs
Sw
it
ch Ports and
Netw
ork
Cab
les
Twisted-Pair Cable/Connector Pin-Outs
Auto-MDIX Feature:
The 10/100/1000-T ports support the IEEE 802.3ab
standard, which includes the “Auto MDI/MDI-X” feature. In the default
configuration, “Auto”, the ports on the Switch 3400 all automatically detect
the type of port on the connected device and operate as either an MDI or MDI-
X port, whichever is appropriate. So for any connection, a straight-through
twisted-pair cable can be used --
you no longer have to use crossover cables
,
although crossover cables can also be used for any of the connections.
If you connect a Switch 3400 twisted-pair port to another switch or hub, which
typically have MDI-X ports, the Switch 3400 port automatically operates as an
MDI port. If you connect it to an end node, such as a server or PC, which
typically have MDI ports, the Switch 3400 port operates as an MDI-X port. In
all cases, you can use standard straight-through cables or crossover cables.
If you happen to use a correctly wired crossover cable, though, the switch will
still be able to automatically detect the MDI/MDI-X operation and link
correctly to the connected device.
N o t e
Using Fixed Configurations.
If the port configuration is changed to any of
the fixed configurations though, for example 100 Mbps/full duplex, the port
operates as MDI-X only and the correct cable type must be used: for
connections to MDI ports, such as end nodes, use a straight-through cable; for
connections to MDI-X ports, such as on hubs and other switches, use a
crossover cable.
Other Wiring Rules:
■
All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-B (not USOC). See “Twisted-Pair Cable Pin
Assignments” later in this appendix for a listing of the signals used on each
pin.
■
For 1000Base-T connections, all four pairs of wires in the cable must be
available for data transmission. See
“Note on 1000Base-T Cable Require-
ments” on page B-1
for more information on 1000Base-T cabling.
■
For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
unshielded twisted-pair cable, as supported by the IEEE 802.3 Type
10Base-T standard.
Summary of Contents for ProCurve 3400cl-24G
Page 1: ...Installation and Getting Started Guide www procurve com ProCurve Series 3400cl Switches ...
Page 2: ......
Page 3: ...ProCurve Series 3400cl Switch Installation and Getting Started Guide ...
Page 52: ... This page is intentionally unused ...
Page 72: ... This page is intentionally unused ...
Page 84: ... This page is intentionally unused ...
Page 105: ... This page is intentionally unused ...
Page 106: ... This page is intentionally unused ...
Page 107: ......