Mode Conditioning Patch Cord for
Gigabit-LX
The following information applies to installations in which multimode fiber-
optic cables are connected to a Gigabit-LX port.
N o t e
Mode Conditioning Patch Cord cables only apply to one Gigabit operation.
Mode Conditioning Patch Cord cables are not supported for 10 Gigabit
operation.
Unlike Gigabit-SX, which connects to only multimode fiber-optic cabling,
Gigabit-LX can use either single-mode or multimode cable. Multimode cable
has a design characteristic called “Differential Mode Delay”, which requires
that the transmission signals be “conditioned” to compensate for the cable
design and thus prevent resulting transmission errors. Since Gigabit-SX is
designed to operate only with multimode cable, Gigabit-SX mini-GBICs can
provide that transmission conditioning internally.
Gigabit-LX mini-GBICs, since they are designed to operate with both single-
mode and multimode cable, do not provide the transmission conditioning
internally. Thus, under certain circumstances, depending on the cable used
and the lengths of the cable runs, an external
Mode Conditioning Patch
Cord
may need to be installed between the Gigabit-LX transmitting device
and the multimode network cable to provide the transmission conditioning.
If you experience a high number of transmission errors on the Gigabit-LX
ports, usually CRC or FCS errors, you may need to install one of these patch
cords between the Gigabit-LX port in your switch and your multimode fiber-
optic network cabling, and between the Gigabit-LX transmission device and
the network cabling at the other end of the multimode fiber-optic cable run.
A patch cord must be installed at both ends.
The patch cord consists of a short length of single-mode fiber cable coupled
to graded-index multimode fiber cable on the transmit side, and only
multimode cable on the receive side. The section of single-mode fiber is
connected in such a way that it minimizes the effects of the differential mode
delay in the multimode cable.
N o t e
If you are using good quality graded-index multimode fiber cable that adheres
to the standards listed on
page 2-5
, there should not be a need to use mode
conditioning patch cords. This is especially true if the fiber runs in your
network are relatively short. If you are using
single-mode
fiber-optic cabling,
there is no need to use mode conditioning patch cords. Connect the single-
mode network cable directly to the Gigabit-LX mini-GBIC.
Summary of Contents for ProCurve 3400cl-24G
Page 1: ...Installation and Getting Started Guide www procurve com ProCurve Series 3400cl Switches ...
Page 2: ......
Page 3: ...ProCurve Series 3400cl Switch Installation and Getting Started Guide ...
Page 52: ... This page is intentionally unused ...
Page 72: ... This page is intentionally unused ...
Page 84: ... This page is intentionally unused ...
Page 105: ... This page is intentionally unused ...
Page 106: ... This page is intentionally unused ...
Page 107: ......