Rack option kit

Part number

Description

Roof Mount Fan kit

257413-B21 (110V)

--or--

257414-B21 (220V)

The Roof Mount fan kit enhances
natural convection cooling within
the rack

Server/utility shelf kit

253449-B21

The Server/utility Shelf kit holds
rack components inside of the
rack.

Side Panel kit

P9L15A (42U, 1075mm)

--or--

P9L16A (42U, 1200mm)

--or--

P9L17A (48U, 1075mm)

--or--

P9L18A (48U, 1200mm)

The Side Panel kit provides
enclosures for the sides of a rack.

This kit comes standard with HPE
Advanced G2 Series racks.

Stabilizer kit

BW932A (600mm)

--or--

BW933A (800mm)

Anti-tip stabilizer kits provide
stability and support when
equipment is installed, removed,
or accessed within the rack. Heavy
duty Stabilizer kits should be used
when a single racked component
exceeds 200lbs.

Heavy Duty V2 Stabilizer kit

BW961A (600mm)

Anti-tip stabilizer kits provide
stability and support when
equipment is installed, removed,
or accessed within the rack. Heavy
duty Stabilizer kits should be used
when a single racked component
exceeds 200lbs.

This kit is only available for
600mm wide racks.

Depth Adjustable Fixed Rail kit

332558-B21

This kit contains two - 48.26cm (19
inches) to 78.74cm (31 inches) -
depth adjustable rails that mount
rack-mountable servers, storage
boxes, UPSs, and networking
products in third party racks. It
also allows for most third-party
rack-mountable products to be
mounted in racks.

2U Universal Locking Drawer

361591-B21

This locking drawer is used to
store instruction manuals, CD,
tools or other items that is required
frequently used at the rack and
requires safekeeping. Kit includes
sliding rails and lock with keys.

18

Rack options

Summary of Contents for P9K37A

Page 1: ...HPE Enterprise G2 Series Racks User Guide Part Number 878359 001 Published March 2017 Edition 1 Abstract This document provides guidance for using HPE Enterprise G2 Series racks ...

Page 2: ...ware Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Links to third party websites take you outside the Hewlett Packard Enterprise website Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise website Acknowledgments Intel Itan...

Page 3: ...emoving the side panels 10 Stabilizing requirements 11 Rack Tie down Option kit 12 Installing components 13 Installing components in a rack 13 Installing the cage nuts 13 Installing the 1 4 turn hook and loop cabling strap clips 14 Rack options 16 Ordering rack options 16 HPE Rack Baying kit options 19 HPE Enterprise G2 Series rack specifications 20 Support and other resources 23 Accessing Hewlett...

Page 4: ...Warranty information 25 4 Contents ...

Page 5: ...d Enterprise website Space requirements When deciding where to place your rack At least 1219 mm 48 in of clearance is needed all the way around the pallet and above the rack to enable the removal of the packing material At least 1219 mm 48 in of clearance is needed in front of the rack to enable the door to open completely At least 762 mm 30 in of clearance is needed in the rear of the rack to pro...

Page 6: ...s TMRA Airflow requirements Hewlett Packard Enterprise rack mountable products typically draw in cool air through the front and exhaust warm air out through the rear of the rack The front door of the rack therefore must be adequately ventilated to enable ambient room air to enter the rack and the rear door must be adequately ventilated to enable the warm air to escape the rack Do not block the ven...

Page 7: ...s 2 This symbol indicates the presence of risk of personal injury as the rack may become unstable if more than one component within the rack is extended for any reason WARNING To reduce the risk of injury only extend one component at a time 3 This symbol is to ensure that the rack is adequately stabilized before extending a component outside of the rack Consult your documentation for specific deta...

Page 8: ...ized reseller 2 1 3 Item Description Quantity 1 Door side panel key 2 2 Leveling pads 4 3 Baying bracket 24 4 4 Baying bracket 6mm 4 Required tools The following tools are required for installation Flathead screwdriver T 25 Torx driver T 30 Torx driver Adjustable wrench Cage nut insertion tool For comfort and efficiency while setting up your rack use power tools where applicable Removing the rack ...

Page 9: ...top hinge pin up and then tilt the door away from the rack 3 Lift the door up to remove it from the bottom hinge Store the door in an upright position taking care to protect it from damage Removing the rear doors 1 Unlock the doors and then open them Removing the front door 9 ...

Page 10: ...Lift the rear doors off of the hinge brackets 1 and remove them from the rack 2 Store the doors in an upright position taking care to protect them from damage 1 2 Removing the side panels Procedure 1 Unlock the top side panel 2 Tilt the panel at a 45 degree angle and slide it away from the rack 10 Removing the side panels ...

Page 11: ...epending on your rack configuration There are four stabilizer kit options The standard 600 mm 23 6 in or 800 mm 31 5 in front foot is required with deployments of stand alone racks Rack rows with four or more bayed racks without a single rack mountable component exceeding 99 8 kg 220 lb do not need a stabilizer kit installed The heavy duty 600 mm 23 6 in front foot is required when a single rack m...

Page 12: ...ing the racks with components The weight of the rack must rest on the leveling feet Rack Tie down Option kit The Rack Tie Down Option kit is used to secure racks to the floor 1 2 3 4 Hewlett Packard Enterprise recommends having the building structural engineer drill the holes Secure the rack to the floor with approved bolts and washers For more information see the rack options installation guide f...

Page 13: ... into the rack 3 Prepare and install the component into the rack and secure it 4 Attach the cable management arm to the rack and then to the component 5 Attach any cables and power cords Be sure to adhere to all cautions and warnings contained in the individual component installation instructions 6 Remove the cable access panel and route the cables Installing the cage nuts Use the cage nut inserti...

Page 14: ... clips 2 Turn the hook and loop cabling strap clip at a slight angle to align the square nut with the square hole on the rack 3 Insert the square nut into the square hole on the rack and then turn it at a 45 degree angle to lock it into place 4 Bundle rack cables as required 14 Installing the 1 4 turn hook and loop cabling strap clips ...

Page 15: ...Installing components 15 ...

Page 16: ...ponents 1U Universal Filler Panel BW928A 10pk or BW929A 100pk This kit ensures proper airflow within the rack Airflow Optimization kit BW930A The Airflow Optimization kit Improves rack airflow of your rack by preventing hot air recirculation to the front of the rack Ballast kit 120672 B21 The Ballast kit provides additional stability and support when heavy equipment is installed removed or accesse...

Page 17: ...s with HPE Rack Top Cable trays to run overhead cables Hook and loop Cabling Strap Clip kit 379820 B21 Hook and loop Cabling Strap kits enable you to manage your cable configurations 1 4 Turn Hook and Loop Cabling Strap kit BW963A 10 PK or BW964A 100 PK Hook and loop Cabling Strap kits enable you to manage your cable configurations Custom Door Branding kit BW935A The Custom Door Branding kit enabl...

Page 18: ...en a single racked component exceeds 200lbs Heavy Duty V2 Stabilizer kit BW961A 600mm Anti tip stabilizer kits provide stability and support when equipment is installed removed or accessed within the rack Heavy duty Stabilizer kits should be used when a single racked component exceeds 200lbs This kit is only available for 600mm wide racks Depth Adjustable Fixed Rail kit 332558 B21 This kit contain...

Page 19: ...cy rack 42u x 600mm x 1075mm Legacy rack 42u x 600mm x 1200mm HPE Advanced Enterprise G2 racks 42u x 600mm x 1075mm HPE Advanced Enterprise G2 racks 42u x 600mm x 1200mm Legacy rack 42u x 600mm x 1000mm Baying kit P9L12A Offset baying kit BW952A N A N A N A Legacy rack 42u x 600mm x 1075mm Offset baying kit BW952A Baying kit P9L12A Offset baying kit BW941A Baying kit P9L12A N A Legacy rack 42u x 6...

Page 20: ... 597 92 mm 23 54 in 1 300 20 mm 51 29 in 1 131 61 kg 3 000 lb HPE 42U 600x1200mm Enterprise G2 Shock rack Part Number U height Width Depth Dynamic CTO load gross Static Load P9K40A 42U 597 92 mm 23 54 in 1 300 20 mm 51 29 in 1 133 98 kg 2 500 lb 1 131 61 kg 3 000 lb HPE 42U 800x1075mm Enterprise G2 Pallet rack Part Number U height Width Depth Dynamic CTO load gross Static Load P9K41A 42U 797 80 mm...

Page 21: ...r U height Width Depth Dynamic CTO load gross Static Load P9K48A 42U 797 80 mm 31 41 in 1 300 20 mm 51 19 in 1 133 98 kg 2 500 lb 1 131 61 kg 3 000 lb HPE 48U 600x1075mm Enterprise G2 Shock rack Part Number U height Width Depth Dynamic CTO load gross Static Load P9K50A 48U 597 92 mm 23 54 in 1 125 22 mm 44 30 in 1 133 98 kg 2 500 lb 1 131 61 kg 3 000 lb HPE 48U 600x1200mm Enterprise G2 Pallet rack...

Page 22: ...allet rack Part Number U height Width Depth Dynamic CTO load gross Static Load P9K57A 48U 797 80 mm 31 41 in 1 300 20 mm 51 19 in 1 133 98 kg 2 500 lb 1 131 61 kg 3 000 lb HPE 48U 800x1200 Enterprise G2 Shock rack Part Number U height Width Depth Dynamic CTO load gross Static Load P9K58A 48U 797 80 mm 31 41 in 1 300 20 mm 51 19 in 1 133 98 kg 2 500 lb 1 131 61 kg 3 000 lb HPE 48U 800x1200 Enterpri...

Page 23: ...duct documentation to identify the recommended software update method To download product updates Hewlett Packard Enterprise Support Center www hpe com support hpesc Hewlett Packard Enterprise Support Center Software downloads www hpe com support downloads Software Depot www hpe com support softwaredepot To subscribe to eNewsletters and alerts www hpe com support e updates To view and update your ...

Page 24: ... you to repair your product If a CSR part needs to be replaced it will be shipped directly to you so that you can install it at your convenience Some parts do not qualify for CSR Your Hewlett Packard Enterprise authorized service provider will determine whether a repair can be accomplished by CSR For more information about CSR contact your local service provider or go to the CSR website http www h...

Page 25: ...on and compliance data including RoHS and REACH see www hpe com info ecodata For Hewlett Packard Enterprise environmental information including company programs product recycling and energy efficiency see www hpe com info environment Turkey RoHS material content declaration Ukraine RoHS material content declaration Warranty information To view the warranty for your product see the Safety and Compl...

Reviews: