1.
Environment with high concentration of dust.
2.
Environment with high concentration of salt in the air surrounding and cooling the product.
3.
Environment with high concentration of corrosive gases such as Sulfur Dioxide(SO
2
),
Hydrogen Sulfide(H
2
S), Chlorine(CL
2
), and Ammonia(NH
3
), etc.
Please reference the Software End User License Agreement and Hardware Limited Warranty
for Hewlett Packard Enterprise Networking for more details.
www.hpe.com/networking/warranty
.
Safety and Regulatory Information for 1850 Office Connect Switch Series
For important safety, environmental, and regulatory information, see Safety and Compliance
Information for Server, Storage, Power, Networking, and Rack Products, available at
http://
www.hpe.com/support/Safety-Compliance-EnterpriseProducts
.
AC power frequency
range
Maximum AC Current
Rated AC voltage
Electrical
:
Non-PoE
50/60 Hz
0.9 A
nl
100-127 V
nl
HPE 1850-8XG Switch
(JL169A)
0.5 A
200–240 V
50/60 Hz
0.6 A
nl
100-127 V
nl
HPE 1850-24G Switch
(JL170A)
0.4 A
200–240 V
50/60 Hz
1.0 A
nl
100-127 V
nl
HPE 1850-48G Switch
(JL171A)
0.6 A
200–240 V
AC power
frequency range
PoE+ available
power
Maximum AC
Current
Rated AC voltage
Electrical: PoE+
50/60 Hz
185 W
2.5 A
nl
100-127 V
nl
HPE 1850-24G-PoE+
(185W) Switch (JL172A)
1.3 A
200–240 V
50/60 Hz
370 W
5.0 A
100-127 V
nl
HPE 1850-48G-PoE+
(370W) Switch (JL173A)
nl
2.
4
A
200–240 V
1850-8XG, 1850-24G, 1 4.82A 850-48G, 1850-24G-PoE+, 1850-48G-PoE+ Switches
Environmental:
0°C to 40°C (32°F to 104°F)
Operating Temperature:
15% to 95% at 40°C (104°F), non-condensing
Operating relative humidity:
-40°C to 70°C (-40°F to 158°F)
Non-operating/storage
temperature:
15% to 95% at 65°C (149°F), non-condensing
Non-operating/storage
relative humidity:
3.0 km (10,000 ft)
Maximum Operating
Altitude:
4.57 km (15,000 ft)
Maximum non-operating
altitude
Side-to-side
Airflow direction
EN 60950–1:2006 +A11:2009 +A1:2010 +A12:2011+A2:2013
Safety — EU
IEC60950–1:2005 +A1:2009 +A2:2013
Safety — World-Wide
CSA 22.2 No 60950–1–7 2nd; UL60950–1 2nd
Safety — North American
Safety:
EN 60825-1:2007/IEC 60825-1:2007, Class 1
Lasers:
10