Removal and replacement procedures 29
4.
Remove the foot.
To replace the component, reverse the removal procedure.
Access panel
To remove the component:
1.
Power down the server (on page
2.
Do one of the following:
•
Extend the server from the rack (on page
•
Remove the tower front bezel. ("
3.
If the locking latch is locked, use a T-15 Torx screwdriver to unlock the latch.
4.
Slide the access panel back about 1.5 cm (0.5 in).
5.
Lift and remove the access panel.
NOTE:
Turn the access panel over to locate the hood labels. These labels provide information on installing
various options, flexible memory configurations, LED status indicators, and switch settings.
To replace the component, reverse the removal procedure.
Rack bezel
To remove the component:
1.
Power down the server (on page
2.
Extend the server from the rack (on page
3.
Remove the access panel ("