101
6 Tests and Error Messages
MaxiLife Test Sequence and Error Messages
Operating System Boot Phase
If no error message has been displayed at this stage of the system startup by
the BIOS, the operating system is launched. The LCD status panel will
display the system platform and a “smiling icon.”
Run-Time Errors
During the normal usage of the PC Workstation (and at boot), MaxiLife
continually monitors vital system parameters. These include: temperature
errors, fan malfunctions, power voltage drops and CPU problems.
Test
Error Code
Beep Codes
Action to Take
Incompatible memory modules
Mem Miscompare
3
Check that the memory modules are of
the same speed and type.
Presence of continuity modules in the RIMM
sockets
RIMM Continuity
3
Check that the RDRAM continuity
modules are installed
Compatibility speed rating of installed RDRAM
modules
RIMM speed
3
Check that the installed RDRAM modules
have the same speed ratings
Compatibility of installed RDRAM modules
RIMM Devices
3
The 32 device limit per RDRAM has been
exceeded.
Presence of memory modules
No RIMM
3
Check that the memory modules are
correctly installed
Availability of video controller. It is checked by
the BIOS. If an error is detected, it is not a fatal
one and the BIOS will continue its execution
normally.
No Video
4
Check that the video controller is
correctly installed
Note: No error is detected if a monitor is
not connected to an installed video
controller. This is not a fatal error and
the BIOS will continue its normal
execution.
Summary of Contents for Kayak XU700
Page 1: ...hp kayak xu700 Technical Reference Manual ...
Page 6: ...Contents 6 ...
Page 26: ...26 1 System Overview Documentation ...
Page 62: ...62 2 System Board Assigned Device Interrupts ...
Page 80: ...80 4 Mass Storage Devices ...
Page 96: ...96 5 HP BIOS BIOS Addresses ...
Page 121: ...121 7 Connectors and Sockets Ethernet UTP Connector ...