1-4
Hardware Installation
Install the Module
Installation Procedure
1.
Use a Torx T-10 or flat-bladed screwdriver to unscrew the screws in the
cover plates over the slot where you will install the module. Store the
cover plates for possible future use.
2.
Hold the module by its bulkhead, taking care not to touch the metal
connectors or components on the board.
3.
Open the extractor handles.
4.
Insert the module, aligning with the guides in the slots, and slide it into
the slot until it is fully inserted.
5.
Once the module is fully inserted, use the extractor handles to set it
completely.
6.
Tighten the screws.
Figure 1-2. Module Being Installed
The procedure to replace or remove a module is described in “Replacing or
Removing a Module” on page C-6 in Appendix C: “Hardware Components.”
Insert module into the guides
and slide in until fully
inserted
.
Open extractor handles.