5981-9636EN Rev. 1, 01/29/2004
To learn more, please visit www.hp.com/go/hpprocurve.
© 2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change
without notice. The only warranties for HP products and services are set forth in the express warranty statements
accompanying such products and services. Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
HP ProCurve Switch 5300xl Series
Specifications
Standard configurations
8-slot chassis has an integrated
switching engine and a power
supply. Supports a maximum
of 192 10/100 ports or
32 Gigabit ports.
Switch 5372xl:
72 10/100 ports
(3 x J4820A);
5 open module slots
Switch 5308xl:
8 open module slots
4-slot chassis has an integrated
switching engine and a power
supply. Supports a maximum
of 96 10/100 ports or
16 Gigabit ports.
Switch 5348xl:
48 10/100 ports
(2 x J4820A);
2 open module slots
Switch 5304xl:
4 open module slots
Physical characteristics
Dimensions
– Switch 5308xl and 5372xl:
17.4 × 15.3 × 8.75 in.
(44.2 × 38.9 × 22.23 cm)
(5U height)
– Switch 5304xl and 5348xl:
17.4 × 15.3 × 5.25 in.
(44.2 × 38.9 × 13.34 cm)
(3U height)
Weight
– Switch 5372xl:
31.3 lb (14.20 kg)
– Switch 5308xl:
26.8 lb (12.16 kg)
– Switch 5348xl:
24.85 lb (11.27 kg)
– Switch 5304xl:
21.85 lb (9.91 kg)
Memory and processor
Fabric: Motorola PowerPC
@ 200 MHz, 12 MB flash,
32 MB SDRAM
Module: ARM7 @ 66 MHz,
128 KB flash, 128 KB SRAM,
18 MB RDRAM
Packet buffer size: 36 MB
Dual flash
Mounting
Mounts in an EIA-standard 19 in.
telco rack or equipment cabinet
(hardware included); horizontal
surface mounting only
Performance
Latency: < 6 µs FIFO
Throughput: 48 mpps
Switch fabric speed: 76.8 Gbps
Address table size: 10,000 entries
Environment
Operating
– Temperature: 32° F to 104° F
(0° C to 40° C)
– Relative Humidity: 15% to 95%
at 104° F (40° C), non-
condensing
Non-operating/Storage
– Temperature: –40º F to 158º F
(–40º C to 70º C)
– Relative humidity: 15% to 95%
@ 149º F (65º C)
Altitude: up to 15,091 ft. (4.6 km)
Electrical characteristics
Heat dissipation:
– 8 slot chassis-
2,116 BTU/hr
– 4 slot chassis-
1,178 BTU/hr
Power: 620W
Voltage: 100–127 VAC/
200–240 VAC
Current: 8.2A/3.8A
Frequency: 50/60 Hz
Safety
cUL (CSA 950);
EN 60950/IEC 950;
NOM-019-SCFI-1994;
UL 1950 3rd edition
Emissions
FCC Class A;
EN 55022/CISPR 22 Class A;
VCCI Class A
Immunity
EN 55024/CISPR 24
ESD: IEC 61000-4-2, 4 kV CD,
8 kV AD
Radiated: IEC 61000-4-3, 3V/m
EFT/Burst: IEC 61000-4-4, 1.0 kV
(power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5, 1 kV/2 kV
AC
Conducted: IEC 61000-4-6, 3V
Power frequency magnetic field:
IEC 61000-4-8, 1A/m, 50 or
60 Hz
Voltage dips and interruptions:
IEC 61000-4-11, >95%
reduction, 0.5 period;
30% reduction, 25 periods
Harmonics: EN 61000-3-2/
IEC 61000-3-2
Flicker: EN 61000-3-3/
IEC 61000-3-3
Management
HP ProCurve Manager (included);
HP ProCurve Manager Plus;
Command line interface; Web
browser; configuration menu;
out-of-band management
(serial RS-232C)
Standards and protocols
RFC 783 TFTP;
RFC 951 BootP;
RFC 1542 BootP;
RFC 854 Telnet;
RFC 768 UDP;
RFC 792 ICMP;
RFC 793 TCP;
RFC 826 ARP;
RFC 2030 Simple Network Time
Protocol;
IEEE 802.3x Flow Control;
DHCP Relay;
RFC 3376 IGMPv1/v2/v3;
RFC 2453 RIPv2;
RFC 2328 OSFPv2 (includes route
authentication);
IGMPv3;
IEEE 802.1D Spanning Tree;
IEEE 802.1w Rapid Convergence
Spanning Tree;
IEEE 802.1s Multiple Spanning
Trees;
IEEE 802.3ad Link Aggregation
Control Protocol;
Cisco Fast EtherChannel
®
(FEC);
RFC 2474 DiffServ Precedence;
RFC 2597 DiffServ Assured
Forwarding (AF);
RFC 2598 DiffServ Expedited
Forwarding (EF);
RFC 1492 ;
RFC 2138 RADIUS;
RFC 2866 RADIUS accounting;
SSHv1/SSHv2 Secure Shell;
Secure Sockets Layer (SSL);
IEEE 802.1X Network Login;
IEEE 802.1Q VLAN tagging;
IEEE 802.1Q GVRP;
SNMPv1/v2c/v3;
Cisco Discovery Protocol (CDP);
HTML and telnet management;
RFC 1493 Bridge MIB;
PIM Dense;
RFC 1213 MIB II;
RFC 2096 IP Forwarding Table
MIB;
RFC 2737 Entity MIB;
RFC 2863 Evolution of Interface;
RFC 2665 Ethernet MIB;
RFC 1058 RIP;
RFC 1724 RIPv2 MIB;
RFC 2819 Four groups of RMON:
1 (statistics), 2 (history),
3 (alarm), and 9 (events);
Extended RMON;
sflow;
RFC 2021 RMON probe
configuration (RMON v2);
RFC 2668 802.3 MAU MIB;
RFC 2613 SMON;
RFC 2674 802.1p and
IEEE 802.1Q Bridge MIB;
RFC 1850 OSPF MIB;
RFC 2618 RADIUS Client MIB;
RFC 2620 RADIUS Accounting
MIB