8
3. Plan the Installation
When installed, the back of the NJ2000G extends into a wall for 0.5
inches. Because the depth of some wall openings differs, observe the
following requirements and recommendations before you install the
NJ2000G:
•
Make sure that the wall opening where the NJ2000G is being
installed complies with the NEMA-WD6 standard, as described in this
diagram:
•
Make sure that the distance between the back of the NJ2000G and
the inside of the wall is at least 1.5 inches (3 inches is recommended).
NOTE:
If you are installing the NJ2000G into a wall junction box, make sure
that there is enough space between the back of the NJ2000G and the inside
of the junction box to maintain an acceptable bend radius on the cable.
•
To ensure proper horizontal cabling functionality, adhere to the following
network cabling standards during installation:
•
ANSI/TIA/EIA-568
Commercial Building Telecommunications Cabling Standard
•
ANSI/TIA/EIA-569
Commercial Building Standard for Telecommunications Pathways and
Spaces