14BSAS HBA 335
Table 15-86
HPSAS_DeviceIndication: Enclosure Fan status changed to OK
Property name
Property implementation
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional
property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional
property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation
Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
Table 15-87
HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity 3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Fan status has changed to
Degraded. An enclosure has detected there may a
problem with one or more of the fans.
AlertingMangedElement WBEM
Path
of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2
(CIMObjectPath)
AlertType
5 (Device Alert)
EventID 305
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP
SAS