Specifications
Environmental specifications
Specification
Value
—
Operating
10°C to 35°C (50°F to 95°F)
Nonoperating
–30°C to 60°C (–22°F to 140°F)
Relative humidity (noncondensing)
—
Operating
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
Nonoperating
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended. The extended
range is 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level. An altitude derating of 1.0°C per every
175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft) is applicable.
Mechanical specifications
Apollo n2600 Gen10 Plus Chassis
Specifications
Value
Dimensions
—
Height
87.50 mm (3.44 in)
Depth
924.00 mm (36.38 in)
Width
440.00 mm (17.32 in)
Weight (approximate maximum values)
—
Empty chassis (chassis without the drives, power supplies, RCM
module, server nodes, and server blanks)
13.17 kg (29.03 lb)
8 SFF drive configuration
40.18 kg (88.58 lb)
24 SFF drive configuration
46.73 kg (103.02 lb)
Specifications