background image

1-4

GENERAL INFORMATION

DESCRIPTION

The Model E3620A Dual Output Power Supply is a compact,
constant voltage/current limiting supply that delivers two iso-
lated 0 to 25 V outputs rated at 1 A. It is an ideal power supply
for design and breadboard work where single or dual voltages
are required. Each output voltage is continuously  variable
throughout its range and separate current limit circuits protect
each output against overload or short circuit damage.

Connections to the outputs are made to binding post type ter-
minals on the front panel. The outputs can be used individu-
ally or in combination to satisfy any number of output
demands. The positive or negative terminal of each output
can be grounded or each output can be left floating. A chassis
ground terminal is located on the front panel of the supply.

The front panel also contains a line switch, output voltage
controls, an autoranging digital voltmeter and a single-range
digital ammeter, and two meter select pushbutton switches.
The meter pushbuttons select both voltage and current
monitoring for the output V1 and V2. The supply is furnished
with a detachable, 3-wire grounding  type line cord. The ac
line fuse is an extractor type fuseholder on the rear heat sink.

SAFETY CONSIDERATIONS

This product is a Safety Class I instrument, which means that
it is provided with a protective earth ground terminal. This ter-
minal must be connected to an ac source that has a 3-wire
ground receptacle. Review the instrument rear panel and this
manual for safety markings and instructions before operating
the instrument. Refer to the Safety Summary page at the
beginning of this manual for a summary of general safety
information. Specific safety information is located at the
appropriate places in this manual.

SAFETY AND EMC REQUIREMENTS

This power supply is designed to comply with the following
safety and EMC(Electromagnetic Compatibility) require-

ments:

B

„

IEC 1010-1(1990)/EN 61010 (1993): Safety Require-
ments for Electrical Equipment for Measurement, Control, 
and Laboratory Use

„

CSA C22.2 No.231: Safety Requirements for Electrical 
and Electronic Measuring and Test Equipment

„

UL 1244: Electrical and Electronic Measuring and Testing 
Equipment

„

EMC Directive 89/336/EEC: Council Directive entitled 
Approximation of the Laws of the Member States relating 
to Electromagnetic Compatibility

„

 EN 55011(1991) Group 1, Class B/CISPR 11 (1990): 
Limits and Methods of Radio Interference Characteristics 
of Industrial, Scientific, and Medical(ISM) Radio-
Frequency Equipment

„

EN 50082-1(1992) /
IEC 801-2(1991): Electrostatic Discharge Requirements
IEC 801-3(1984): Radiated Electromagnetic Field

Requirements

IEC 801-4(1988): Electrical  Fast  Transient/Burst 

Requirements

INSTRUMENT AND MANUAL IDENTIFICATION

A serial number identifies your power supply. The serial num-
ber encodes the country of manufacture, the week of the lat-
est significant design change, and a unique sequential
number. The letter "KR" designates Korea as the country of
manufacture, the first one digit indicates the year (4=1994,
5=1995, and so forth), and the second two digits indicate the
week. The remaining digits of the serial number are a unique,
five-digit number assigned sequentially.

If the serial number on your supply does not agree with those
on the title page of the manual, a yellow  Change Sheet is
supplied with the manual to explain the difference between
your instrument and the instrument described by this manual.
The Change Sheet may also contain information for correct-
ing errors in the manual.

OPTIONS

Options 0E3 and 0E9 determine which line voltage is
selected at the factory. The standard unit is configured for
115 Vac ± 10%, 47-63 Hz input.

Option No.

Description

0E3:

230 Vac ± 10%, 47-63 Hz Input

0E9:

100 Vac ± 10%, 47-63 Hz Input

ACCESSORY

The accessory listed below may be ordered from your local
Hewlett-Packard Sales Office either with the power supply or
separately. (Refer to the list at the rear of the manual for
address.)

HP Part No.

Description

5063-9240

Rack Kit for mounting one or two 3 1/2" high
supplies in a standard 19" rack

The rack mount kit is needed for rack mounting of the
E3620A power supply.

ORDERING ADDITIONAL MANUALS

One manual is shipped with each power supply. (Option 910 
is ordered for each extra manual.) Additional manuals may 
also be purchased separately for your local Hewlett-Packard 
sales office (see the list at the rear of this manual for 
addresses). Specify the model number, serial prefix, and the 
HP Part Number provided on the title page.

SPECIFICATIONS

Instrument specifications are listed in Table 1. These specifi-
cations are performance standards or limits against which the
instrument is tested.

Summary of Contents for E3620A

Page 1: ...7387 32 5 6833 3 02 6953 23 5 7 1 0 18 25 167580 176 7 6 5 180 56 574533434 1 29 RU LQVWUXPHQWV ZLWK 6HULDO 1XPEHUV DERYH 574533434 D FKDQJH SDJH PD EH LQFOXGHG1 0DQXDO 3DUW 1R1 69530 3334 XJXVW 4 GLWLRQ 9 ü ...

Page 2: ... personnel Do not replace compo nents with power cable connected Under certain conditions dangerous voltages may exist even with the power cable removed To avoid injuries always disconnect power dis charge circuits and remove external voltage sources before touching components DO NOT SERVICE OR ADJUST ALONE Do not attempt internal service or adjustment unless another person capable of rendering fi...

Page 3: ...NSTALLATION DATA 1 5 Location and Cooling 1 5 Outline Diagram 1 6 Rack Mounting 1 6 INPUT POWER REQUIREMENTS 1 6 Power Cable 1 6 OPERATING INSTRUCTIONS 1 6 INTRODUCTION 1 6 CONTROLS 1 6 Line Switch 1 6 Voltage and Current Metering 1 6 Voltage Controls 1 6 TURN ON CHECKOUT PROCEDURE 1 7 OPERATION 1 7 Overload Protection Circuits 1 7 Operation Beyond Rated Output 1 7 Connecting Load 1 7 Series Opera...

Page 4: ...6 EEC Council Directive entitled Approximation of the Laws of the Member States relating to Electromagnetic Compatibility EN 55011 1991 Group 1 Class B CISPR 11 1990 Limits and Methods of Radio Interference Characteristics of Industrial Scientific and Medical ISM Radio Frequency Equipment EN 50082 1 1992 IEC 801 2 1991 Electrostatic Discharge Requirements IEC 801 3 1984 Radiated Electromagnetic Fi...

Page 5: ...KRRW ZLOO QRW H FHHG 4 9 LI WKH RXWSXW FRQWURO LV VHW IRU OHVV WKDQ 4 91 I WKH FRQWURO LV VHW IRU 4 9 RU KLJKHU WKHUH LV QR RYHUVKRRW1 0 7 5 85 318 RI RXWSXW 5 FRXQWV DW 58R 8R 0 7 5 5 62 87 21 9ROWDJH 43 P9 3 WR 53 9 433 P9 DERYH 53 9 XUUHQW 4 P 0 16 216 54516 PP 14 PP 67817 PP 17 LQ 618 LQ 4619 LQ 7 813 NJ 4413 OEV QHW 9158 NJ 461 OEV VKLSSLQJ 167 7 21 1 7 163 7 21 HIRUH VKLSPHQW WKLV LQVWUXPHQW...

Page 6: ...re 1 Outline Diagram OPERATING INSTRUCTIONS INTRODUCTION This section describes the operating controls and indicators turn on checkout procedures and other operating consider ations for the Model E3620A Dual Output Power Supply Before applying power to the supply check the label on the heat sink to make certain that the supply s line voltage option agrees with the line voltage to be used If the op...

Page 7: ... and currents greater than its rated maximum outputs if the line voltage is at or above its nominal value Operation can be extended up to 5 over the rated output without damage to the supply but performance can not be guaranteed to meet specifications above the rated output of 0 to 25 V at 1 A Connecting Load Connect each load to the power supply output terminals using separate pairs of connecting...

Page 8: ...e output terminals of the supply helps to supply high current pulses of short duration during constant voltage operation Any capacitance added exter nally will improve the pulse current capability but will decrease the load protection provided by the current limiting circuit A high current pulse may damage load components before the average output current is large enough to cause the current limit...

Page 9: ......

Page 10: ...URP DQRWKHU FRXQWU 3 VKDOO SD IRU UHWXUQ RI SURGXFWV WR XVWRPHU1 DUUDQW VHUYLFHV RXWVLGH WKH FRXQWU RI LQLWLDO SXUFKDVH DUH LQFOXGHG LQ 3 V SURGXFW SULFH RQO LI XVWRPHU SD V 3 LQWHUQD0 WLRQDO SULFHV GHILQHG DV GHVWLQDWLRQ ORFDO FXUUHQF SULFH RU 8161 RU HQHYD SRUW SULFH 1 I 3 LV XQDEOH ZLWKLQ D UHDVRQDEOH WLPH WR UHSDLU RU UHSODFH DQ SURGXFW WR FRQGLWLRQ DV ZDUUDQWHG WKH XVWRPHU VKDOO EH HQWLWOHG W...

Page 11: ...From 0 5 of full scale 2 counts at 25 C 5 C To 0 5 of output 2 counts at 25 C 5 C Change 2 Make the following changes to the Replaceable Parts List on page A 12 to A 13 Old HP Part Number New HP Part Number Part Description 8120 1378 8120 8767 Power cord for STD 0E9 8120 1689 8120 8768 Power cord for 0E3 1853 0950 1853 0590 TRANSISTOR 2N4036 SI TO 5 PD 1W Rack Mounting Kits The part numbers for th...