80
HP E1459A Register Definitions
Bit 14 is the MODID bit. When a "0" is returned in bit 14 then the module
has been selected with a high state on the P2 MODID line. If a "1" is
returned then the module has not been selected. This bit is read only.
Edge Interrupt
Status Register
The Edge Interrupt Status Register (base + 06
h
) indicates if an edge interrupt
has been detected for any of the 4 ports. There are 4 bits used in this register,
one for each port. A bit will remain asserted ("1") in this register until all
edge events for a port have been cleared. Bit 0 is used for Port 0, bit 1 for
Port 1, bit 2 for Port 2, and bit 3 for Port 3. These bits reflect the state of the
INTR lines available on the terminal module. The INTR lines will be
asserted when a bit is "1" in this register. This register has no effect if it is
written.
Edge Interrupt Status Register (base + 06h)
INTRX = Edge interrupt for port 0 - 3. A "1" means an edge event has been
detected within the corresponding port and a "0" means one hasn't. A bit set
to "1" will only return to "0" by reading the interrupt register that caused the
edge detection to occur.
Data Available
Status Register
The Data Available Status Register (base + 08
h
) indicates if an external
trigger has occurred for any of the 4 ports. There are 4 bits used in this
register, one for each port. A bit will be asserted when the DAV ENAB bit
and the INT/EXT bit are set ("1") in the command register for a port, and an
external trigger occurs. (An external trigger occurs on a negative edge). Bit
0 is used for Port 0, bit 1 for Port 1, bit 2 for Port 2, and bit 3 for Port 3.
These bits reflect the state of the DAV lines available on the terminal
module. The DAV lines will be asserted when a bit is "1" in this register.
This register has no effect if it is written.
Data Available Register (base + 08h
)
DAVX = Data available in Port 0 - 3. A "1" means that new data has been
latched into the channel data register for that port. A "0" means it has not
been triggered yet. A bit set to "1" will only return to "0" by reading the
DAV register associated with that port.
b + 6
h
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Write
No Effect
Read
Always Returns FFF
h
INTR3
INTR2
INTR1
INTR0
b + 8
h
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Write
No Effect
Read
Always Returns FFF
h
DAV3
DAV2
DAV1
DAV0
Summary of Contents for E1459A
Page 4: ...4 Contents ...
Page 8: ...8 Notes ...
Page 10: ......
Page 28: ...28 Installing and Configuring the HP E1459A ...
Page 61: ...HP E1459A SCPI Command Reference 61 Figure 3 1 HP E1459A Status System Register Diagram ...
Page 72: ...72 HP E1459A SCPI Command Reference ...
Page 74: ...74 HP E1459A Specifications ...
Page 103: ...HP E1459A Register Definitions 103 1970 END ...
Page 104: ...104 HP E1459A Register Definitions ...
Page 106: ...106 Error Messages ...
Page 110: ...110 Index ...