Removal and replacement procedures 25
Remove the FBWC module
Use this procedure to remove the FBWC module when servicing other components. To replace a failed or
broken module, see "FBWC module (on page
)."
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
CAUTION:
Do not operate the storage blade with the access panel open or removed. Operating
the storage blade in this manner results in improper airflow and improper cooling that can lead
to thermal damage.
To remove the component:
1.
Back up all data on the storage blade.
2.
Power down the partner server blade (on page
3.
Remove the storage blade (on page
4.
Remove the access panel (on page
5.
Open the drive drawer. Extend the drawer to gain access to the FBWC module.
6.
Remove the cache module from the system board.