EBIPA Settings - Device Bay iLO Processors
Domain:
Subnet Mask: 255.255.255.0 Gateway: 172.22.aaa.bbb
DNS Server1: 0.0.0.0 Server2: 0.0.0.0
Server3: 0.0.0.0
Bay Enabled EBIPA Address Current Address Device Type
--- ------- --------------- --------------- ------------
1 Yes 172.22.a.b 172.22.a.b Server Blade
1A No N/A [Absent]
1B No N/A [Absent]
2 Yes 172.22.a.b 172.22.a.b Server Blade
.
.
SHOW OA NETWORK ALL
Onboard Administrator #1 Network Information:
Name: OA-1
DHCP: Disabled
IP Address: 172.22.aaa.bbb
Netmask: 255.255.255.0
Gateway Address: 172.22.aaa.bbb
Primary DNS: 0.0.0.0
Secondary DNS: 0.0.0.0
MAC Address: 9C:8E:99:29:xy:yx
Link Settings: Auto-Negotiation, 1000 Mbit, Full Duplex
Link Status: Active
Enclosure IP Mode: Disabled
Onboard Administrator #2 Network Information:
Name: OA-2
DHCP: Disabled
IP Address: 172.22. aaa.bbb
Netmask: 255.255.255.0
Gateway Address: 172.22. aaa.bbb
Primary DNS: 0.0.0.0
Secondary DNS: 0.0.0.0
MAC Address: 9C:8E:99:29:xy:xy
Link Settings: Auto-Negotiation, 1000 Mbit, Full Duplex
Link Status: Active
Enclosure IP Mode: Disabled
Troubleshooting CAMNet issues
Check the proper cabling between all the enclosures within a complex using the
HR> test
camnet <location>
command:
OA1> show hr
OA1 HR> test camnet enclosure9/midplane0
Invoke CAMNet Test on location 0x0900FFFF01FFFF69
CAMNet test has executed without finding faults
Success: CAMNet test completed with no errors
Test complete
OA1 HR> test camnet enclosure1/blade1
Invoke CAMNet Test on location 0x0100FF01FFFFFF94
CAMNet test has executed without finding faults
Success: CAMNet test completed with no errors
84
Troubleshooting