Chapter 1
69
Remove/Replace System Components
Converting Your System for Desktop or Rack-Mount Use
place. See Figure 1-93. Note that before the bezel and its end caps are placed on the
system, the system must be installed in the rack as described in the rack installation
instructions provided with your rack-mount kit.
Figure 1-93. Place the Bezel with End Caps on the System
5. Plug-in the workstation that you just rack mounted and set the fan speed. To set the fan
speed, use the Boot Console Handler (bch) and follow this procedure.
A. Turn on the system and press the
Tab
key until the select display message appears.
You should select the display frequency and resolution that are best for you.
B. Stop the boot process by pressing any key before the ten-second limit. This gets you
to the bch Main Menu. You will only need to do this if you have
autoboot
turned on;
otherwise, the system stops at the bch Main Menu. When the Main Menu prompt
appears, type:
Main Menu: Enter command > configuration
C. Enter the following command at the Configuration Menu prompt:
Configuration Menu: Enter command > FanChoice RackMount
D. Return to the Main Menu and enter this command at the prompt to continue
booting:
Configuration Menu: Enter command > boot