background image

security to prevent unauthorized entry. Side panels are also lockable* allowing for your entire rack
row to be secure

HP MCS Key Features

HP MCS Key Features

HP MCS Key Features

HP MCS Key Features

Cooling Capacity of up to 35kW

Cooling Capacity of up to 35kW

Cooling Capacity of up to 35kW

Cooling Capacity of up to 35kW - MCS has been designed to support a full load of blade
servers, which, at their maximum configuration require a power load of 35kW. The MCS unit will
provide over 2700 CFM of cool air distributed along the full height of the rack.
Power Input Redundancy

Power Input Redundancy

Power Input Redundancy

Power Input Redundancy - Automatically detects power failure and switches to alternate source.
Environmental Control and Safety

Environmental Control and Safety

Environmental Control and Safety

Environmental Control and Safety - The MCS features full environmental control of the cooled air
temperature being placed in front of the servers. The heat exchanger unit features safety quick
disconnect valves that prevent accidental chilled water leakage during service. A water leak
detector ships standard with the MCS. Alarms can be sent via SNMP traps to Systems Insight
Manager (SIM).
Hot-swappable components

Hot-swappable components

Hot-swappable components

Hot-swappable components - Fans and heat exchangers can be replaced while the unit is
operating allowing for great flexibility in servicing the MCS.

Industry Standard Support

Industry Standard Support

Industry Standard Support

Industry Standard Support All rack products are 19 inch RETMA standard and will support select third-party equipment. For

additional rack information, please refer to the HP 10000 G2 Series rack QuickSpecs at:

http://h18004.www1.hp.com/products/servers/proliantstorage/racks/10000series.html

Components

Components

Components

Components

The following brick level options/components do not have individual HP Care Pack Services. These items
will be included in product HP Care Pack Services into which they are installed.

Disk Drives

Tape Drives

CD/DVD ROM

SCSI Hubs in SBBs

Adapters

Bus Converters

Backplane RAID
Controllers

Power Supplies

Cabling

Fans

Service and Support

Service and Support

Service and Support

Service and Support
Offerings

Offerings

Offerings

Offerings (HP Care Pack
Services)

HP Modular Cooling System: One year warranty, parts only (1-0-0)
HP 10642 G2 Series Rack: Three year warranty, parts only (3-0-0)

NOTE:

NOTE:

NOTE:

NOTE: Certain restrictions and exclusions apply. Consult the HP Customer Support Center for details.

Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:

Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and
VMware-base d IT solutions helping to deliver high level of application availability. Response times
range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution

NOTE:

NOTE:

NOTE:

NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or
resellers or visit our worldwide Web site on the internet at: 

http://www.hp.com/hps/carepack

NOTE:

NOTE:

NOTE:

NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us
at: 

http://www.hp.com/hps

NOTE:

NOTE:

NOTE:

NOTE: Additional information regarding worldwide limited warranty and technical support is available
at: 

http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html

NOTE:

NOTE:

NOTE:

NOTE: For additional information on Server Services, Rack and Power Options, please visit:

http://h20219.www2.hp.com/services/cache/111072-0-0-225-121.html

QuickSpecs

HP Modular Cooling System

HP Modular Cooling System

HP Modular Cooling System

HP Modular Cooling System

Standard Features

DA - 12404   Worldwide — Version 8 — September 17, 2008

Page 5

Summary of Contents for AF058A

Page 1: ...p from 30kW CTO capability of up to 2000 Lbs dynamic load The MCS now ships standard with heavy duty Shock Pallet to support shipping the MCS integrated with IT equipment Customers may now use the services of Factory Express or other integration services QuickSpecs HP Modular Cooling System HP Modular Cooling System HP Modular Cooling System HP Modular Cooling System Overview DA 12404 Worldwide Ve...

Page 2: ...iling configuration Ships pre attached to HP 10642 G2 Series Rack Environmental Monitor and control with SNMP integration to Systems Insight Manager SIM Hot swappable heat exchangers and fans Power Input Redundancy for dual power source Condensate Evacuation system to prevent condensation from entering air stream 2750 CFM of chilled air placed in front of the servers and or blades Site Preparation...

Page 3: ...em MCS HP Modular Cooling System WW CTO ready AF098A HP 10642 G2 Rack Rear Extension Kit NOTE NOTE NOTE NOTE Extension kit is required when racking p Class Blade enclosure combined with Monitored PDU s AF058A MCS Onsite Installation NOTE NOTE NOTE NOTE Install MCS per the product user installation manual All MCS units ship with shock pallet for CTO UE005E NOTE NOTE NOTE NOTE The Rack Rear Extensio...

Page 4: ...E NOTE NOTE NOTE A loaded MCS unit should only be moved by professional movers HP 10000 G2 Series HP 10000 G2 Series HP 10000 G2 Series HP 10000 G2 Series Rack Rack Rack Rack All HP rack mountable products are designed to fit our industry standard 19 inch wide racks Racks and rack mountable components are typically described using U measurements One U is 1 75 44 45 mm high The MCS ships attached t...

Page 5: ...nstalled Disk Drives Tape Drives CD DVD ROM SCSI Hubs in SBBs Adapters Bus Converters Backplane RAID Controllers Power Supplies Cabling Fans Service and Support Service and Support Service and Support Service and Support Offerings Offerings Offerings Offerings HP Care Pack Services HP Modular Cooling System One year warranty parts only 1 0 0 HP 10642 G2 Series Rack Three year warranty parts only 3...

Page 6: ...limited warranty statements accompanying such products and services NOTE NOTE NOTE NOTE Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein QuickSpecs HP Modular Cooling System HP Modular Cooling System HP Modular Cooling System HP Modular Cooling System Standard Features DA 12404 Worldwide...

Page 7: ...ys Kits Rack Top Cable Tray 600W 8 Pack 383982 B21 Rack to Rack Adjustable Cable Tray Aisle Transfer Bridge 383984 B21 Rear Extension Kits Rear Extension Kits Rear Extension Kits Rear Extension Kits 10642 G2 Rear Extension Kit 155mm NOTE NOTE NOTE NOTE The 10642 G2 extension kit is required when using HP monitored PDU s AF058A Service and Support Service and Support Service and Support Service and...

Page 8: ...ent Cooling agent Cooling agent Primary or auxiliary chilled water supply Condensate evacuation Condensate evacuation Condensate evacuation Condensate evacuation tube tube tube tube Yes Air temperature Air temperature Air temperature Air temperature regulation regulation regulation regulation Yes Heat exchangers Heat exchangers Heat exchangers Heat exchangers 3 Fans Fans Fans Fans 3 Rack Front doo...

Page 9: ...ns USA Japan Japan Japan Japan NEMA L6 20P Input Connections Input Connections Input Connections Input Connections International International International International IEC309 16 Amps Power Cords Power Cords Power Cords Power Cords 2 for redundancy Power input redundancy Power input redundancy Power input redundancy Power input redundancy Yes with auto failover switch Environment Environment Env...

Page 10: ...ts returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other...