Supported software
Supported software
Supported software
Supported software
Telnet,RADIUS, SNMP, WebTools, Enhanced group Management, Advanced Zoning, Fabric Watch,
Data Center Fabric Manager
Management access
Management access
Management access
Management access
10/100 Ethernet (RJ-45), serial port
Diagnostics
Diagnostics
Diagnostics
Diagnostics
POST and embedded online/offline diagnostics
Back-to-front airflow,
Back-to-front airflow,
Back-to-front airflow,
Back-to-front airflow,
power inlet on port side
power inlet on port side
power inlet on port side
power inlet on port side
1 u, 19-in.–EIA compliant
Dimensions
Dimensions
Dimensions
Dimensions
Width
Width
Width
Width
16.87 in (42.86 cm)
Height
Height
Height
Height
1.69 in (4.29 cm)
Depth
Depth
Depth
Depth
12.1 in (30.73 cm)
Weight
Weight
Weight
Weight
8.8 lb (4.0 kg)
Environment
Environment
Environment
Environment
Temperature
Temperature
Temperature
Temperature
Operating
Operating
Operating
Operating
32° to 104° F (0° to 40° C)
Non-operating
Non-operating
Non-operating
Non-operating
-58° to 212° F (-50° to 100° C)
Humidity
Humidity
Humidity
Humidity
Operating
Operating
Operating
Operating
20% to 85% non condensing at 104° F (40° C)
Non-operating
Non-operating
Non-operating
Non-operating
10% to 85% , non condensing at 158° F (70° C)
Altitude
Altitude
Altitude
Altitude
Up to 9,800 ft (3,000 m)
Shock
Shock
Shock
Shock
20 G, 6 ms, half sine
Vibration
Vibration
Vibration
Vibration
Operating
Operating
Operating
Operating
.5 G, 5-500-5 Hz
Non-operating
Non-operating
Non-operating
Non-operating
2 G, 5-5 kHz
Power
Power
Power
Power
Supported power range
Supported power range
Supported power range
Supported power range
Nominal
Nominal
Nominal
Nominal
100 to 240 VAC, 2.0 A
Operational
Operational
Operational
Operational
90 to 264 VAC
Frequency
Frequency
Frequency
Frequency
47 to 63 Hz
© Copyright 2009 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
QuickSpecs
HP StorageWorks 4/16 SAN Switch and 4/16 SAN Switch
HP StorageWorks 4/16 SAN Switch and 4/16 SAN Switch
HP StorageWorks 4/16 SAN Switch and 4/16 SAN Switch
HP StorageWorks 4/16 SAN Switch and 4/16 SAN Switch
Power Pack Family
Power Pack Family
Power Pack Family
Power Pack Family
Technical Specifications
DA - 12343 Worldwide — Version 11 — January 26, 2009
Page 13