HP 5500 EI & 5500 SI Switch Series 

Installation Guide 
 

 

 

Part number: 5998-1710 
Document version: 6W101-20130630 

 

Summary of Contents for 5500-24G-SFP EI TAA

Page 1: ...HP 5500 EI 5500 SI Switch Series Installation Guide Part number 5998 1710 Document version 6W101 20130630 ...

Page 2: ...IS MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material The only warranties for HP products and services are set forth in the express warranty statements accom...

Page 3: ...ding conductor buried in the earth ground 15 Grounding the switch by using the AC power cord 16 Installing removing a power supply 16 Installing a power supply 16 Removing a power supply 17 Connecting the power cord 18 Connecting the AC power cord 18 Connecting the PSR150 D PSR150 D1 to a 48 VDC power source 19 Connect the switch to a 12 VDC output RPS 20 Connecting the switch to a 52 to 55 VDC ou...

Page 4: ...4G EI 2 slots 5500 24G EI TAA 2 slots 5500 24G SI 2 slots 39 5500 48G EI 2 slots 5500 48G EI TAA 2 slots 5500 48G SI 2 slots 40 5500 24G SFP EI 2 slots 5500 24G SFP EI TAA 2 slots 41 5500 24G PoE EI 2 slots 5500 24G PoE EI TAA 2 slots 5500 24G PoE SI 2 slots 42 5500 48G PoE EI 2 slots 5500 48G PoE EI TAA 2 slots 5500 48G PoE SI 2 slots 43 Technical specifications 43 Chassis dimensions and weights ...

Page 5: ...t 54 SFP port 54 Combo interface 55 LEDs 55 System status LED 56 Power supply status LEDs 56 RPS status LED 56 Port mode LED 57 Seven segment LED 57 10 100 1000Base T Ethernet port LED 58 SFP port status LED 59 Interface card status LED 60 Support and other resources 61 Contacting HP 61 Subscription service 61 Related information 61 Documents 61 Websites 61 Conventions 62 Index 64 ...

Page 6: ...d damaging the units Examining the installation site The 5500 EI and 5500 SI switches must be used indoors You can mount your switch in a rack or on a workbench but make sure Adequate clearance is reserved at the air inlet and exhaust vents for ventilation The rack or workbench has a good ventilation system The rack is sturdy enough to support the switch and its accessories The rack or workbench i...

Page 7: ...I sources from outside or inside of the switch and application system adversely affect the switch in a conduction pattern of capacitance coupling inductance coupling electromagnetic wave radiation or common impedance including the grounding system coupling To prevent EMI take the following actions If AC power is used use a single phase three wire power receptacle with protection earth PE to filter...

Page 8: ... Installation tools Flathead screwdriver Phillips screwdriver Needle nose pliers Wire stripping pliers Diagonal pliers ESD preventive wrist strap Blow dryer All these installation tools are user supplied ...

Page 9: ...per proof seal on a mounting screw on the chassis cover intact and if you want to open the chassis contact your local HP agent for permission Otherwise HP shall not be liable for any consequence caused thereby Figure 1 Hardware installation flow ...

Page 10: ...i ng by using only front mounting brackets Yes see Rack mounting by using front mounting brackets and a rack shelf No 5500 24G SFP EI 2 slots 5500 24G SFP EI TAA 2 slots 360 mm 14 17 in No Yes see Rack mounting by using front mounting brackets and a rack shelf Yes see Rack mounting by using front and rear mounting brackets 5500 24G PoE EI 2 slots 5500 24G PoE EI TAA 2 slots 5500 24G PoE SI 2 slots...

Page 11: ...6 screw NOTE The M6 screws for attaching the brackets to a rack are user supplied Table 4 shows the mounting bracket shipment for different switch models Table 4 Mounting bracket kit shipped with the 5500 EI and 5500 SI switches Chassis Front mounting brackets Rear mounting brackets 5500 24G EI 2 slots 5500 24G EI TAA 2 slots 5500 48G EI 2 slots 5500 48G EI TAA 2 slots 5500 24G SI 2 slots 5500 48G...

Page 12: ... using only the front mounting brackets 1 Wear an ESD preventive wrist strap and make sure it makes good skin contact and is well grounded 2 Verify that the rack is well grounded and can support the weight of the switch chassis and all its accessories 3 Unpack the front mounting brackets and the screws for attaching the brackets to the switch chassis 4 Align the round holes in one bracket with the...

Page 13: ... 5500 SI switches To mount a switch in a 19 inch rack by using the front mounting brackets and a rack shelf 1 Wear an ESD preventive wrist strap and make sure it makes good skin contact and is well grounded 2 Verify that the rack is well grounded and can support the weight of the switch chassis and all its accessories 3 Attach the rack shelf horizontally in a proper position in the rack 4 Unpack t...

Page 14: ...ounting brackets and the screws for attaching the brackets to the switch chassis 3 Align the round holes in one front mounting bracket with the holes in the front mounting position of the switch chassis and use the removed screws to attach the mounting bracket to the chassis as shown in Figure 4 4 Repeat the previous step to attach the other front mounting bracket to the chassis 5 Unpack the rear ...

Page 15: ...igure 7 Figure 7 Attaching the rear mounting brackets to a rack 1 Rear square holed post 2 Rear mounting bracket 9 One person supports the chassis bottom with one hand holds the front part of the chassis with the other hand and pushes the chassis into the rack gently Make sure the load bearing screws closely contact with the upper edges of the rear mounting brackets as shown in Figure 8 ...

Page 16: ... bracket 10 The other person aligns the oval holes in the front brackets with the mounting holes in the front rack posts and attaches the front mounting brackets with M6 screws user supplied to the front rack posts as shown in Figure 9 Make sure the front and rear mounting brackets have securely attached the switch in the rack ...

Page 17: ...a workbench 1 Verify that the workbench is sturdy and well grounded 2 Place the switch with bottom up and clean the round holes in the chassis bottom with dry cloth 3 Attach the rubber feet to the four round holes in the chassis bottom 4 Place the switch with upside up on the workbench IMPORTANT Ensure good ventilation and 10 cm 3 9 in of clearance around the chassis for heat dissipation Avoid pla...

Page 18: ... is available at the installation site connect the grounding cable to the grounding strip WARNING Connect the grounding cable to the grounding system in the equipment room Do not connect it to a fire main or lightning rod CAUTION For the 5500 24G SFP EI 2 slots and 5500 24G SFP EI TAA 2 slots switches follow the direction shown in Figure 11 to connect the grounding cable to avoid affecting the ins...

Page 19: ...ble as appropriate for connecting to the grounding strip 6 Peel 5 mm 0 20 in of insulation sheath by using a wire stripper and insert the bare metal part through the black insulation covering into the end of the ring terminal 7 Secure the metal part of the cable to the ring terminal with a crimper cover the joint with the insulation covering and heat the insulation covering with a blow dryer to co...

Page 20: ...ger angle iron or steel tube into the earth ground to serve as a grounding conductor The dimensions of the angle iron must be at least 50 50 5 mm 1 97 1 97 0 20 in The steel tube must be zinc coated and its wall thickness must be at least 3 5 mm 0 14 in Weld the yellow green grounding cable to the angel iron or steel tube and treat the joint for corrosion protection Figure 14 Grounding the switch ...

Page 21: ...ct in the power outlet is not connected to the ground report the problem and reconstruct the grounding system Figure 15 Grounding through the PE wire of the AC power cord 1 Three wire AC power cable 2 Chassis rear panel NOTE To guarantee the grounding effect use the grounding cable provided with the switch to connect to the grounding strip in the equipment room as long as possible Installing remov...

Page 22: ...ctly orient the power supply with the power supply slot grasp the handle of the power supply with one hand and support its bottom with the other and slide the power supply slowly along the guide rails into the slot see callout 1 in Figure 16 The slot is foolproof If you cannot insert the power supply into the slot re orient the power supply rather than use excessive force to push it in 5 Fasten th...

Page 23: ... 48G EI TAA 2 slots 5500 24G SI 2 slots 5500 48G SI 2 slots AC input Connecting the AC power cord RPS input Connect the switch to a 12 VDC output RPS 5500 24G PoE EI 2 slots 5500 24G PoE EI TAA 2 slots 5500 48G PoE EI 2 slot 5500 48G PoE EI TAA 2 slot 5500 24G PoE SI 2 slots 5500 48G PoE SI 2 slots AC input Connecting the AC power cord RPS input Connecting the switch to a 52 to 55 VDC output RPS 5...

Page 24: ...ply and insert the plug into the power receptacle see callout 1 in Figure 18 The power receptacle is foolproof If you cannot insert the plug into the receptacle re orient the plug rather than use excessive force to push it in 3 Tighten the screws on the plug with a flat blade screwdriver to secure the plug in the power receptacle see callout 2 in Figure 18 4 Connect the two wires at the other end ...

Page 25: ...onnecting to the switch correctly orient the plug with the RPS receptacle on the switch chassis and insert the plug into the receptacle see callout 1 in Figure 20 The RPS receptacle is foolproof If you cannot insert the plug into the receptacle re orient the plug rather than use excessive force to push it in 4 Tighten the screws on the plug with a flat blade screwdriver to secure the plug in the R...

Page 26: ...the power cord to the RPS Figure 21 Connecting the RPS cable to the 52 to 55 VDC RPS receptacle of the switch Installing removing an interface card This section applies to all 5500 EI and 5500 SI switches For the interface cards available for the switches see Interface cards This section uses the LSPM2SP2P interface card as an example to describe the procedures of installing and removing an interf...

Page 27: ...ewdriver to attach the interface card in the slot see callout 2 in Figure 23 Figure 23 Installing an interface card NOTE Put away the removed filler panel for future use When you tighten the captive screws the torque must not be higher than 0 4 N m Removing an interface card CAUTION Do not touch the surface mounted components directly with your hands Do not use too much force during the operation ...

Page 28: ...e it makes good skin contact is well grounded 2 Correctly orient one connector of the cable with the port and insert the cable connector into the port Removing a dedicated CX4 SFP cable 1 Wear an ESD preventive wrist strap and make sure it makes good skin contact and is well grounded 2 Hold the cable connector and pull the pull latch of the connector to remove the cable from the switch Verifying t...

Page 29: ... a terminal Connecting the console cable Console cable A console cable is an 8 core shielded cable with a crimped RJ 45 connector at one end for connecting to the console port of the switch and a DB 9 female connector at the other end for connecting to the serial port on the console terminal Figure 25 Console cable Connection procedure To connect a terminal for example a PC to the switch 1 Plug th...

Page 30: ...ters To configure and manage the switch you must run a terminal emulator program on the console terminal The following are the required terminal settings Bits per second 9 600 Data bits 8 Parity None Stop bits 1 Flow control None Emulation VT100 To set terminal parameters for example on a Windows XP HyperTerminal 1 Select Start All Programs Accessories Communications HyperTerminal The Connection D...

Page 31: ... by the HyperTerminal connection 4 Set Bits per second to 9600 Data bits to 8 Parity to None Stop bits to 1 and Flow control to None and click OK Figure 28 Setting the serial port parameters 5 Select File Properties in the HyperTerminal window ...

Page 32: ...27 Figure 29 HyperTerminal window 6 On the Settings tab set the emulation to VT100 and click OK Figure 30 Setting terminal emulation in Switch Properties dialog box ...

Page 33: ...onsole port settings on the switch Power on the switch During the startup process you can access Boot ROM menus to perform tasks such as software upgrade and file management The Boot ROM interface and menu options differ with software versions For more information about Boot ROM menu options see the software matching release notes for the device After the startup completes you can access the CLI t...

Page 34: ...itches or 5500 SI switches into a virtual switch called an IRF fabric or IRF virtual device for flattened network topology and high availability scalability and manageability NOTE An IRF fabric cannot have both 5500 EI and 5500 SI switches IRF fabric setup flowchart Figure 31 IRF fabric setup flowchart To set up an IRF fabric ...

Page 35: ...tches except the master switch automatically reboot and the IRF fabric is established Planning IRF fabric setup Planning IRF fabric size and the installation site Choose switch models and identify the number of required IRF member switches depending on the user density and upstream bandwidth requirements The switching capacity of an IRF fabric equals the total switching capacities of all member sw...

Page 36: ...the internal connection between IRF member switches Each IRF member switch has two IRF ports IRF port 1 and IRF port 2 To use an IRF port you must bind physical ports to it When connecting two neighboring IRF member switches you must connect the physical ports of IRF port 1 on one switch to the physical ports of IRF port 2 on the other switch You can bind several physical ports to an IRF port to c...

Page 37: ...ns use CX4 SFP cables or twisted pair cables For more information see Interface cards and SFP SFP XFP transceiver modules and SFP CX4 cables If 2 port interface cards are used and the IRF links are not aggregate You can connect the interface card in slot 1 MOD 1 on a member switch to the MOD 1 or MOD 2 card on its neighboring switch Connect the left port on one interface card to the right port on ...

Page 38: ... connect to the left port on the 2 port interface card Figure 36 Cable connections for an IRF fabric with 1 port interface cards Configuring basic IRF settings After you install the IRF member switches power on the switches and log in to each IRF member switch see HP 5500 EI 5500 SI Switch Series Fundamentals Configuration Guide to configure their member IDs member priorities and IRF port bindings...

Page 39: ...abric and the remote network management station can reach each other 3 Use Telnet web or SNMP to access the IRF fabric from the network management station See HP 5500 EI 5500 SI Switch Series Fundamentals Configuration Guide 4 Verify that you can manage all member switches as if they were one node 5 Display the running status of the IRF fabric by using the commands in the table bellow Task Command...

Page 40: ...e can cause the power module to stop working and enter the protection state RPS DC input If the system status LED or RPS status LED is off an RPS input failure has occurred Verify the following items The switch is securely connected to the RPS The RPS is correctly working The operating temperature of the switch is in the normal range and the power supply has good ventilation Over temperature can c...

Page 41: ...front panel of an HP 5500 24G SFP EI 2 slots or 5500 24G SFP EI TAA 2 slots switch and the LEDs on the power supply to identify a power supply failure If the power supply system is correctly working the power supply LEDs are steady green If the LEDs behave in any other way see Table 13 verify the following items The power cord is correctly connected The power supply meets the requirement The opera...

Page 42: ...ation terminal would display nothing or garbled text No terminal display If the configuration terminal displays nothing after the switch is powered on verify the following items The power supply is supplying power to the switch The console cable is correctly connected The console cable has no problem and the terminal settings are correct Garbled terminal display If terminal display is garbled veri...

Page 43: ... Interface Slots 5500 24G SFP EI 2 slots JG249A HP 5500 24G SFP EI TAA Switch with 2 Interface Slots 5500 24G SFP EI TAA 2 slots JD369A HP 5500 24G SI Switch with 2 Interface Slots 5500 24G SI 2 slots JD370A HP 5500 48G SI Switch with 2 Interface Slots 5500 48G SI 2 slots PoE JG241A HP 5500 24G PoE EI Switch with 2 Interface Slots 5500 24G PoE EI 2 slots JG252A HP 5500 24G PoE EI TAA Switch with 2...

Page 44: ... mode LED Mode 8 System status LED PWR 9 RPS status LED RPS 10 Interface card 1 status LED MOD1 11 Interface card 2 status LED MOD2 12 Port LED mode switching button Figure 38 Rear panel 1 AC power input 2 RPS receptacle shipped with a protective cover 3 Grounding screw 4 Interface card slot 1 MOD1 5 Interface card slot 2 MOD2 NOTE The 5500 24G EI 2 slots 5500 24G EI TAA 2 slots and 5500 24G SI 2 ...

Page 45: ... RPS 8 Interface card 1 status LED MOD1 9 Interface card 2 status LED MOD2 10 Port LED mode switching button 11 1000Base X SFP port 12 1000Base X SFP port LED Figure 40 Rear panel 1 AC power input 2 RPS receptacle shipped with a protective cover 3 Grounding screw 4 Interface card slot 1 MOD1 5 Interface card slot 2 MOD2 NOTE The 5500 48G EI 2 slots 5500 48G EI TAA 2 slots and 5500 48G SI 2 slots s...

Page 46: ...e 42 Rear panel 1 Grounding screw 2 Power supply slot 1 3 Power supply slot 2 4 Interface card slot 1 MOD1 5 Interface card slot 2 MOD2 NOTE The 5500 24G SFP EI 2 slots and 5500 24G SFP EI TAA 2 slots switches come with the expansion interface card slots covered by filler panels The 5500 24G SFP EI 2 slots and 5500 24G SFP EI TAA 2 slots switches come with one power supply filler panel If you use ...

Page 47: ...it 7 Port mode LED Mode 8 System status LED PWR 9 RPS status LED RPS 10 Interface card 1 status LED MOD1 11 Interface card 2 status LED MOD2 12 Port LED mode switching button Figure 44 Rear panel 1 RPS receptacle 2 AC power input 3 Grounding screw 4 Interface card slot 1 MOD1 5 Interface card slot 2 MOD2 NOTE The 5500 24G PoE EI 2 slots 5500 24G PoE EI TAA 2 slots and 5500 24G PoE SI 2 slots switc...

Page 48: ... MOD2 10 Port LED mode switching button 11 1000Base X SFP port 12 1000Base X SFP port LED Figure 46 Rear panel 1 RPS receptacle 2 AC power input 3 Grounding screw 4 Interface card slot 1 MOD1 5 Interface card slot 2 MOD2 NOTE The 5500 48G PoE EI 2 slots 5500 48G PoE EI TAA 2 slots and 5500 48G PoE SI 2 slots switches come with the expansion interface card slots covered by filler panels Technical s...

Page 49: ...440 420 mm 1 72 17 32 16 54 in 7 5 kg 16 53 lb 5500 48G PoE EI 2 slots 5500 48G PoE EI TAA 2 slots 43 6 440 420 mm 1 72 17 32 16 54 in 8 0 kg 17 64 lb Ports and interface card slots Chassis Console ports 10 100 1000Base T auto sensing Ethernet ports SFP ports Interafce card slots 5500 24G EI 2 slots 5500 24G EI TAA 2 slots 5500 24G SI 2 slots 1 24 4 2 5500 24G PoE EI 2 slots 5500 24G PoE EI TAA 2 ...

Page 50: ...a pair is activated the other port automatically shuts down Environmental specifications Chassis Operating temperature Relative humidity All chassis 0 C to 45 C 32 F to 113 F 10 to 90 noncondensing Power specifications Power input types Chassis AC input power receptacle RPS receptacle Power supply slots 5500 24G SFP EI 2 slots and 5500 24G SFP EI TAA 2 slots N A N A 2 For the available power suppl...

Page 51: ...Chassis Minimum power consumption Maximum power consumption 5500 24G EI 2 slots 5500 24G EI TAA 2 slots 36 W 110 W 5500 24G SI 2 slots 36 W 103 W 5500 24G SFP EI 2 slots 5500 24G SFP EI TAA 2 slots PSR150 A PSR150 A1 JD362A 44 W PSR150 D PSR150 D1 JD366A 30 W 115 W 5500 48G EI 2 slots 5500 48G EI TAA 2 slots 63 W 155 W 5500 48G SI 2 slots 55 W 145 W Power consumption specifications for PoE switche...

Page 52: ...s 1 to 24 and 370 W for ports 25 to 48 90 W 651 W at AC input 921 W at RPS DC input Cooling system All 5500 EI and 5500 SI switches use built in fans for heat dissipation and the airflow is from left to right Chassis Built in fans 5500 24G EI 2 slots 5500 24G EI TAA 2 slots 5500 24G SI 2 slots 5500 48G EI 2 slots 5500 48G EI TAA 2 slots 5500 48G SI 2 slots 4 5500 24G PoE EI 2 slots 5500 24G PoE EI...

Page 53: ...Hz to 63 Hz Output voltage 12 V Max output current 12 5 A Max output power 150 W PSR150 D JD366A PSR150 D1 JD366A Rated input voltage range 48 VDC to 60 VDC Max input voltage range 36 VDC to 72 VDC Output voltage 12 V Max output current 12 5 A Max output power 150 W NOTE The 5500 24G SFP EI 2 slots and 5500 24G SFP EI TAA 2 slots switches support the mix of a PSR150 A PSR150 A1 JD362A and a PSR150...

Page 54: ...two 10 Gbps copper ports Yes See CX4 cables LSPM1XGT2P JG535A Provides two 1 10GBase T Ethernet ports Yes N A NOTE For more information about the interface cards see the user guides for the interface cards SFP SFP XFP transceiver modules and SFP CX4 cables NOTE To guarantee the functionality of the SFP SFP XFP ports use only HP transceiver modules The transceiver modules available for this switch ...

Page 55: ...ansceiver 1550 9 125 N A 40 km 24 86 miles JD063B HP X125 1G SFP LC LH70 Transceiver 1550 9 125 N A 70 km 43 50 miles JD103A HP X120 1G SFP LC LH100 Transceiver 1550 9 125 N A 100 km 62 14 miles JD098B HP X120 1G SFP LC BX 10 U Transceiver TX 1310nm RX 1490nm 9 125 N A 10 km 6 21 miles JD099B HP X120 1G SFP LC BX 10 D Transceiver TX 1490nm RX 1310nm 9 125 N A 10 km 6 21 miles JD089B HP X120 1G SFP...

Page 56: ...ceiver modules coded JD100A and JD101A in pairs 10 GE SFP transceiver modules Product code Module description Central wavelength nm Fiber diameter μm Multimode fiber modal bandwidth MHz km Max transmission distance JD092B HP X130 10G SFP LC SR Transceiver 850 50 125 2000 300 m 984 25 ft 500 82 m 269 03 ft 400 66 m 216 54 ft 62 5 125 200 33 m 108 27 ft 160 26 m 85 3 ft JD093B HP X130 10G SFP LC LRM...

Page 57: ...er modules Product code Module description Central wavelength nm Fiber diameter μm Multimode fiber modal bandwidth MHz km Max transmission distance JD117B HP X130 10G XFP LC SR Transceiver 850 50 125 2000 300 m 984 25 ft 500 82 m 269 03 ft 400 66 m 216 54 ft 62 5 125 220 33 m 108 27 ft 160 26 m 85 3 ft JD108B HP X130 10G XFP LC LR 1310nm Transceiver 1310 9 125 N A 10 km 6 21 miles JD121A HP X135 1...

Page 58: ...ble length JD363B HP X230 Local Connect 50cm CX4 Cable 4X Infiniband 0 5 m 19 69 in JD364B HP X230 Local Connect 100cm CX4 Cable 4X Infiniband 1 m 39 37 in JD365A HP X230 CX4 to CX4 3m Cable 4X Infiniband 3 m 118 11 in Figure 48 CX4 cable 1 Pull latch 2 Connector ...

Page 59: ...00 1000Base T Ethernet port Table 9 10 100 1000Base T Ethernet port specifications Item Specification Connector type RJ 45 Interface standard 10 Mbps half full duplex 100 Mbps half full duplex 1000 Mbps full duplex MDI MDI X auto sensing Max transmission distance 100 m 328 08 ft Transmission medium Category 5 or above twisted pair cable Standards IEEE 802 3i 802 3u 802 3ab SFP port All 5500 EI and...

Page 60: ...tEthernet 1 0 25 GigabitEthernet 1 0 22 GigabitEthernet 1 0 26 GigabitEthernet 1 0 24 GigabitEthernet 1 0 27 GigabitEthernet 1 0 21 GigabitEthernet 1 0 28 GigabitEthernet 1 0 23 5500 48G EI 2 slots 5500 48G EI TAA 2 slots 5500 48G PoE EI 2 slots 5500 48G PoE EI TAA 2 slots 5500 48G SI 2 slots 5500 48G PoE SI 2 slots GigabitEthernet 1 0 49 GigabitEthernet 1 0 46 GigabitEthernet 1 0 50 GigabitEthern...

Page 61: ...s have failed to pass POST Off The switch is powered off Power supply status LEDs Only the 5500 24G SFP EI 2 slots and 5500 24G SFP EI TAA 2 slots switches have power supply status LEDs to show the operating status of the power supplies in the power supply slots Table 13 Hot swappable power supply status LED description LED Status Description PWR1 PWR2 Steady green A power supply is installed in t...

Page 62: ...n Table 16 Port mode LED description LED mark Status Description Mode Steady green The network port LEDs are showing port rates Flashing green 1 Hz available only for the PoE switch models The network port LEDs are showing the status of PoE power supply on the ports Steady yellow The network port LEDs are showing duplex modes Seven segment LED The seven segment LED together with the system status ...

Page 63: ... lowercase c character The switch is a candidate switch for a cluster The LED displays a number The member ID of the switch in an IRF fabric Table 18 Seven segment LED description II Port mode LED Mode status System status LED PWR status Seven segment LED Unit status Description Flashing green 1 Hz PoE mode Steady green The LED displays different signs 0 20 21 40 41 60 61 80 81 100 For example the...

Page 64: ...is not supplying PoE power Steady yellow duplex mode Steady green The port is operating in full duplex mode The port status LED fast flashes when the port is sending or receiving data Steady yellow The port is operating in half duplex mode The port status LED fast flashes when the port is sending or receiving data Flashing yellow 3 Hz POST has failed on the port Off No link is present on the port ...

Page 65: ...es when the port is sending or receiving data Flashing yellow 3 Hz POST has failed on the port Off No link is present on the port Interface card status LED Table 21 Interface card status LEDs description LED mark Status Description MOD1 MOD2 Green The interface card is in position and operating correctly Flashing yellow The switch does not support the interface card model or the interface card has...

Page 66: ...r product at the Subscriber s Choice for Business website http www hp com go wwalerts After registering you will receive email notification of product enhancements new driver versions firmware updates and other product resources Related information Documents To find related documents browse to the Manuals page of the HP Business Support Center website http www hp com support manuals For related do...

Page 67: ...ired syntax choices separated by vertical bars from which you select at least one x y Asterisk marked square brackets enclose optional syntax choices separated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conve...

Page 68: ... network device such as a router switch or firewall Represents a routing capable device such as a router or Layer 3 switch Represents a generic switch such as a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device ...

Page 69: ...t swappable power supplies 48 I Installation tools 3 Installing the switch in a 19 inch rack 5 Installing removing a power supply 16 Installing removing an interface card 21 Interface cards 48 IRF fabric setup flowchart 29 L LEDs 55 M Mounting the switch on a workbench 12 P Planning IRF fabric setup 30 Ports 54 Power specifications 45 Power supply failure 35 Powering on the switch 28 R Related inf...