Note:
InfiniBand cables with QSFP to CX4 connectors are required when the HP BLc 4X DDR InfiniBand
Gen 2 Switch uplinks to an InfiniBand spine interconnect with CX4 connectors.
Figure 2-3 QSFP InfiniBand DDR/QDR Cable
1
2
3
The following list describes the callouts shown in
Figure 2-3
:
1.
InfiniBand cable
2.
QSFP connector release pull tab
3.
QSFP connector
Note:
The InfiniBand cables are not included in this kit and must be purchased separately.
Installing an InfiniBand Cable in the HP BLc 4X DDR InfiniBand Gen 2 Switch
To install an InfiniBand cable in the HP BLc 4X DDR InfiniBand Gen 2 Switch, follow these steps:
1.
Align the InfiniBand cable QSFP connector (see callout 1 in
Figure 2-4
) with the HP BLc 4X
DDR InfiniBand Gen 2 Switch port (see callout 2 in
Figure 2-4
).
2.
Insert the QSFP connector into the HP BLc 4X DDR InfiniBand Gen 2 Switch port (see callout
1 in
Figure 2-5
) until it is fully engaged and locked.
Figure 2-4 Align the InfiniBand Cable with the HP BLc 4X DDR InfiniBand Gen 2 Switch Port
3
1
2
The following list describes the callouts shown in
Figure 2-4
:
2.2 Installing InfiniBand Cables in the HP BLc 4X DDR InfiniBand Gen 2 Switch
13