3–6
Check the Hardware Installation
Perform the following steps to check the hardware installation:
CAUTION: The CD-ROM drive is susceptible to mechanical and electrostatic
shock. When handling the drive, always wear the static strap that came
in the CD-ROM drive kit. Always handle the drive carefully.
1.
Check that the SCSI terminator is connected to the single-ended SCSI port on the rear
I/O panel of the system unit (if there are no external SCSI devices), or that the last
external single-ended SCSI device is terminated.
2.
Attach the static-grounding wrist strap by following the instructions on the package that
contains the strap.
3.
Shut down HP-UX.
NOTICE:
If you are already at the boot administration level, you do not need to
shut down; skip this step and go on to Step 4.
If you are running HP-UX under HP VUE, shut down your system by performing the
shutdown procedure described in the System Owner’s Guide which came with your
workstation.
If you are running HP-UX without HP VUE, shut down your system by typing the fol-
lowing command:
#
/etc/shutdown –h
RETURN
You must have superuser privileges to use the /etc/shutdown command. If you do not
have superuser privileges, contact your system administrator.
If your workstation is part of a cluster, refer to the manual, Managing Clusters of HP
9000 Computers for instructions on shutting down.
4.
Power off the workstation, using the power switch on the front of the workstation.