Antistatic standards

 

HOZAN’s ESD-safe products are controlled with reference to the Japanese standard (RCJS-5-1*) 

which is based on the international standard (IEC61340-5-1).

 

Products which bear the “            “ mark are products to which the standard values 

 (see  table below) apply. The “ESD Standard” listed on each of the product pages denote the 

HOZAN standard for the product.

 

ESD-safe item requirements  

(Excerpted from RCJS-5-1)

 

Item-specific requirements

 

In some cases, the max. EPA ground resistance is increased (usually by 

1 X 10

6

Ω

) for every 250 VAC or 500VDC in order to ensure a minimum 

resistance of 7.5 X  10

5

Ω

. The resistance must maintain  a 1/4 W 

minimum power rating per each 250 VAC or 500 VDC.  

 

EPA ground resistance  

or resistance Rg

Ω

of 

groundable point

 

 

Wrist strap  

not worn

 

Wrist strap  

cord

 

Point to point resistance Rp,  

or ground resistance Re  

Ω

 

Rp

1

×

10

5

  

 

7.5

×

10

5

Re

5

×

10

6

 

**

 

Using a wrist 

strap  

(wrist strap 

system)

 

7.5

×

10

5

Rg 

3.5

×

10

7

 

System requirements

 

**

… 

 

Cautions

 

Be sure to ground.

 

The ESD ground line system must be different from the motor ground line. 

  Failing could cause electric shock.

 

Use care to prevent live wires from making contact with the product. Failing  

  could cause electric shock.

   

Warning

 

Carry out periodical inspections to maintain ESD efficiency of this product.

 

Caution

 

15.05

 

1-2-12 Saiwaicho, Naniwa-ku, Osaka 556-0021, Japan

 

Tel : +81-6-6567-3111

   

F a x  : +81-6-6562-0024

 

* Reliability Center for Electronic Components of Japan (RCJ). 

  

“Protection of Electronic Devices from Electrostatic Phenomena-General Requirements” (RCJS-5-1)

 

Reviews: