HOZAN F-154 Instruction Manual Download Page 3

  

Replacement parts

 

F-154-1  

Coil Cord (10pcs) 

F-154-2

  Wristband (10pcs) 

F-154-3

  Alligator clip (10pcs)

 

 Specifications

 

Attach the wristband to your wrist with the stud facing outside. Always fasten 

the wristband to your wrist.

 

 

Operation

 

Ground the banana plug of the coil cord, connecting F-126 Ground terminal 

sold separately.

 

Attach the socket to the stud of the wristband.

 

1 

2 
3 

 

 

Thank you for purchasing the HOZAN F-154 WRIST STRAP (10PCS). With proper 

care and handling,

 

this fine instrument will provide years of trouble-free 

operation.  Please  read  this  entire  instruction  manual

 

carefully  before 

attempting to place this instrument in service.

 

Please keep this instruction 

manual available for reference.

 

WRIST STRAP (10PCS)

 

INSTRUCTION MANUAL

 

F-154

 

 10 pcs.  

 Cord overall length: 2.0m 

 Cord effective length: 

    1.0m 

 Socket diameter : 10mm 

 With 1M

Ω

resistor  

 ESD Standard :  

    Ground resistance    

    7.5X10

5

Rg

3.5X10

7

Ω

 

                  

  *Being worn

 

Coil cord

 

Socket

 

Wristband

 

Banana plug

 

Adjuster

 

Alligator clip

 

 

Related product

 

F-126  

Ground terminal

 

Reviews: