9. Functions
9.1 Battery Check
Turn the function selector to Batt. Check. This function has
a load which draw about 205mA when test is performed, and
therefore it is doing a worst case battery test.
Then, press the test button, the pointer should be in the
BAT.OK area. During the test, the bat. OK Led (on line battery
check) must lit if the pointer is in the BAT.OK area
9.2 DC Warning
The DC warning buzzer will beep continuously when DC
voltage is higher than 30Vdc on the test probes and the test
button is Not pressed.
The neon light "circuit live" will lit when the voltage on the test
probes is higher than 90Vdc and the test button is not pressed.
9.3 AC Warning
The AC warning buzzer will beep continuously when AC voltage
is higher than 20Vac on the test probes and the test button is
NOT pressed.
The neon light "circuit live" will lit when the voltage on the test
probes is higher than 65Vdc and the test button is NOT pressed.
- 9 -