© 2022 Hoymiles Power Electronics Inc. All rights reserved.
12
Single-phase Microinverter User Manual
B) Connect the AC end cable to the AC male
connector of the first microinverter to
complete the circuit.
C) Connect the other side of the AC end cable to the distribution box, and wire it to the local grid network.
Step 4. Create an Installation Map
A) Peel the removable serial number label
from each microinverter (the position of
the label is shown on the right).
B) Affix the serial number label to the
respective location on the installation
map.
To sheet ______
To
sh
ee
t ____
__
To
s
he
et
____
__
To sheet ______
Sheet_____of_____
Hoymiles Microinverter Installation Map
Please Make N for North
1
A
B
C
D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
COLUMN
ROW
AP040228 V1.2
Customer Information:
DTU Serial Number
Azimuth:
Tilt:
Panel type:
Step 5. Connect PV Modules
A) Mount the PV modules above the
microinverter.
B) Connect the PV modules’ DC cables to
the DC input side of the microinverter.
Step 6. Energize the System
A) Turn on the AC breaker of the branch circuit.
B) Turn on the main AC breaker of the house. Your system will start to generate power after about two
minutes of waiting time.
Step 7. Set Up the Monitoring System
Refer to the DTU User Manual or DTU Quick Installation Guide, and Quick Installation Guide for S-Miles Cloud
(Hoymiles Monitoring Platform) Online Registration to install the DTU and set up your monitoring system.