Hoymiles DTU-W100 3rd Gen User Manual Download Page 4

© 2019 Hoymiles Converter Technology Co., Ltd. All rights reserved.

4

DTU-W100 3 Gen

1.5 Other Information

Product information is subject to change without notice. The user manual will be updated frequently, and
please refer to Hoymiles official website at www.hoymiles.com for the latest version.

2. About Hoymiles Microinverter System

2.1 The Microinverter

It converts the DC output of solar modules into grid-compliant AC power. It sends the output information
of PV panels and the operation data of the microinverters to the DTU, which is the hardware basis of the
panel-level monitoring.

With conversion efficiency up to 96.7% and MPPT efficiency up to 99.9%, Hoymiles microinverters rank
into the first class of the world

s Microinverter industry.

2.2 The DTU

The DTU is the key component in Hoymiles microinverter system. It works as the communication
gateway, which operates between the Hoymiles microinverters and the Hoymiles Monitoring Server. The
DTU communicates with the microinverter wirelessly via 2.4GHz Proprietary RF (Nordic), collecting the
operation data of the system. Meanwhile, the DTU connects to the Internet via router and communicates
with Hoymiles Monitoring Server. The microinverter system operation data will be uploaded to Hoymiles
Monitoring Server via DTU.

2.3 The Hoymiles Monitoring Server

It collects the operation data and status of the microinverters in the system and provides the panel-level

monitoring for the users and maintenance staff. The following diagram shows the Hoymiles
Microinverter system.

Summary of Contents for DTU-W100 3rd Gen

Page 1: ...Version 2 0 April 2020...

Page 2: ...he Microinverter 4 2 2 The DTU 4 2 3 The Hoymiles Monitoring Server 4 3 DTU Installation 5 3 1 System Capacity 5 3 2 Basic Conditions Required 5 3 3 Dimensions 5 3 4 Interface Layout 5 3 5 Local Insta...

Page 3: ...re Doing so may cause death or injury to persons or damage to equipment 1 3 User This manual is only for professional installation and maintenance personnel to use 1 4 Support and Contact Information...

Page 4: ...microinverters rank into the first class of the world s Microinverter industry 2 2 The DTU The DTU is the key component in Hoymiles microinverter system It works as the communication gateway which op...

Page 5: ...ensure the site meets the following requirements Install close to the router Stable Internet reception The straight line distance between DTU and Microinverter shall be less than 5 meters The location...

Page 6: ...y MI under this DTU is working properly and the details for each MI and how many is abnormal and the details for each MI with one glance of eyes C Add the Connection status which will display the sign...

Page 7: ...signal reduction for possible obstacles at the site has been shown below Material Relative signal range reductions Wood Glass 0 10 Stone Pressed cardboard 10 40 Reinforced concrete reduction increase...

Page 8: ...com in advance C Add Station select the Station tab on the bottom then select on the right top side of the page D Select Quick for Single DTU and Profession for Multi DTU E Please fill in the station...

Page 9: ...to view all details once the data start to upload normally it will need around 30 minutes for the first data coming through D Customers can also view the Microinverter generating details via accessing...

Page 10: ...ng details on the computer web page by accessing Hoymiles online monitoring platform at https world hoymiles com 8 View Phone APP Download mobile phone APP by search Hoymiles at App Store IOS or Play...

Page 11: ...nect with Wi Fi Check the distance between router and DTU if it s over the range refer to chapter 3 5 point 2 Check the distance between router and DTU if it s over the range refer to chapter 3 5 poin...

Page 12: ...very 0 5 seconds The search ID is incomplete Re locate the DTU to somewhere close to both router and Microinverter Model DTU W100 Communication to Microinverter Communication method 2 4GHz Proprietary...

Page 13: ...verter Technology Co Ltd All rights reserved 13 DTU W100 3 Gen Size W H D 143mm 33mm 12 5mm Weight KG 0 1 A fixed way Direct power supply Indicator light LED Others Standard EN60950 EN61000 3 2 EN6100...