DTU-G100 3 Gen 

3.5 Local Install Assistant 

Local  Install  Assistant  is  a  new  function  integrated  with  DTU-G100  3rd  Gen,  please  download  the 
Installer App (for installer/distributor use only) first.

 

 

 

 

DTU-G100  has  improved  from  the  previous  generation  of  DTU  product,  and  developed  with  this  new 
function that allows installer:   

 

A. Station overall Inverters status indication allows the installer to see how many MI under this           
DTU is working properly (and the details for each MI) and how many is abnormal (and the details for 
each MI) with one glance of eyes; 
B. Add  the  Connection  status,  which  will  display  the  signal  strength  between  each  MI  with       
connected DTU, so that installer can adjust the DTU installation location accordingly. This function 
will simplify the DTU installation, and avoid the second visit for installer due to the poor connection 
between DTU and certain MI. 
 

Note:

 Please refer to 

Hoymiles Local Install Assistant Technical Note

  for more details. 

 

3.6 System Installation Sequence 

 

 

 

 

3.7 

DTU Installation Procedure

 

 

(1) Install the PV Modules and microinverters 

Please refer to the Microinverter

s Manual or Quick Installation Guide for the detail installation steps. 

1. Install 

Microinverters and 

PV modules

2. Install and power 

on the DTU

3. Create a site on 

Monitoring account

4. View system 

performance 

5. Complete 

installation map 

Summary of Contents for DTU-G100

Page 1: ...Version 2 1 August 2020...

Page 2: ...The DTU 4 2 3 The Hoymiles Monitoring Server 4 3 DTU Installation 5 3 1 System Capacity 5 3 2 Basic Conditions Required 5 3 3 Dimensions 5 3 4 Interface Layout 5 3 5 Local Install Assistant 6 3 6 Sys...

Page 3: ...ng so may cause death or injury to persons or damage to equipment 1 3 User This manual is only for professional installation and maintenance personnel to use 1 4 Support and Contact Information If you...

Page 4: ...microinverters rank into the first class of the world s Microinverter industry 2 2 The DTU The DTU is the key component in Hoymiles microinverter system It works as the communication gateway which op...

Page 5: ...TU can monitor may be reduced 3 2 Basic Conditions Required Before installing the DTU ensure the site meets the following requirements l The straight distance between DTU and Microinverter shall be le...

Page 6: ...glance of eyes B Add the Connection status which will display the signal strength between each MI with connected DTU so that installer can adjust the DTU installation location accordingly This functio...

Page 7: ...te reduction increases with the amount of reinforcement 10 90 Metal Up to 100 Therefore the DTU shall be placed as close to the microinverters as possible at the site to ensure good communication betw...

Page 8: ...te G Click Start binding and choose the angle and tilt base on the installation H Scan the Microinverter ID or you can manually input the ID and click the tick after completing each ID input Press Fin...

Page 9: ...system is energized and the DTU detects the microinverters you need to complete the installation map A Peel the serial number label from the DTU and place it on the installation map B Complete system...

Page 10: ...from there 9 LED indicator working status description Red Light Description Flashes every 1 second No SIM Card Flashes every 0 5 seconds DTU disconnect with server Blue Light Description Flashes ever...

Page 11: ...Direct power supply Display LED indicator light Others Standard EN60950 EN61000 3 2 EN61000 3 3 FCC 15B 15C Indicator Status Description Solution Red LED Flesh in Red every 1 second No SIM Card l Che...