Hoymiles DTU-G100 User Manual Download Page 4

 

                                                  © 2019 Hoymiles Converter Technology Co., Ltd. All rights reserved.

                                                         

4

 

 

 

DTU-G100 3 Gen 

1.5   Other Information 

       

Product information is subject to change without notice. The user manual will be updated frequently, and 
please refer to Hoymiles official website at www.hoymiles.com for the latest version.   
 

2. About Hoymiles Microinverter System 

 

2.1 The Microinverter 

 

It converts the DC output of solar modules into grid-compliant AC power. It sends the output information 
of PV panels and the operation data of the microinverters to the DTU, which is the hardware basis of the 
panel-level monitoring.     

 

With conversion efficiency up to 96.7% and MPPT efficiency up to 99.9%, Hoymiles microinverters rank 
into the first class of the world

s Microinverter industry. 

 

2.2 The DTU 

 

       

The  DTU  is  the  key  component  in  Hoymiles  microinverter  system.  It  works  as  the  communication 
gateway, which operates between the Hoymiles microinverters and the Hoymiles Monitoring Server. The 
DTU communicates with the microinverter wirelessly via 2.4GHz Proprietary RF (Nordic), collecting the 
operation data of the system. Meanwhile, the DTU connects to the Internet via router and communicates 
with Hoymiles Monitoring Server. The microinverter system operation data will be uploaded to Hoymiles 
Monitoring Server via DTU. 

 

2.3 The Hoymiles Monitoring Server 

 

It collects the operation data and status of the microinverters in the system and provides the panel-level 
monitoring  for  the  users  and  maintenance  staff.  The  following  diagram  shows  the  Hoymiles 
Microinverter system. 

 

Summary of Contents for DTU-G100

Page 1: ...Version 2 1 August 2020...

Page 2: ...The DTU 4 2 3 The Hoymiles Monitoring Server 4 3 DTU Installation 5 3 1 System Capacity 5 3 2 Basic Conditions Required 5 3 3 Dimensions 5 3 4 Interface Layout 5 3 5 Local Install Assistant 6 3 6 Sys...

Page 3: ...ng so may cause death or injury to persons or damage to equipment 1 3 User This manual is only for professional installation and maintenance personnel to use 1 4 Support and Contact Information If you...

Page 4: ...microinverters rank into the first class of the world s Microinverter industry 2 2 The DTU The DTU is the key component in Hoymiles microinverter system It works as the communication gateway which op...

Page 5: ...TU can monitor may be reduced 3 2 Basic Conditions Required Before installing the DTU ensure the site meets the following requirements l The straight distance between DTU and Microinverter shall be le...

Page 6: ...glance of eyes B Add the Connection status which will display the signal strength between each MI with connected DTU so that installer can adjust the DTU installation location accordingly This functio...

Page 7: ...te reduction increases with the amount of reinforcement 10 90 Metal Up to 100 Therefore the DTU shall be placed as close to the microinverters as possible at the site to ensure good communication betw...

Page 8: ...te G Click Start binding and choose the angle and tilt base on the installation H Scan the Microinverter ID or you can manually input the ID and click the tick after completing each ID input Press Fin...

Page 9: ...system is energized and the DTU detects the microinverters you need to complete the installation map A Peel the serial number label from the DTU and place it on the installation map B Complete system...

Page 10: ...from there 9 LED indicator working status description Red Light Description Flashes every 1 second No SIM Card Flashes every 0 5 seconds DTU disconnect with server Blue Light Description Flashes ever...

Page 11: ...Direct power supply Display LED indicator light Others Standard EN60950 EN61000 3 2 EN61000 3 3 FCC 15B 15C Indicator Status Description Solution Red LED Flesh in Red every 1 second No SIM Card l Che...

Reviews: