SCHEMATIC WIRE DIAGRAM OF
ADAPTOR ADP- 0241- 05A
Note: This marking is also on the cover of the
Adaptor unit as well as on a label to be placed
next to the wiring diagram of the appliance.
Schematic Wire Diagram of ADP-0241-05A
Activated by an Exhaust Fan Auxiliary
Relay Switch To Control a Furnace Re-
circulating Fan and a Fresh Air Damper.
Damper remains closed during furnace firing.
(See
‘Notes’
for alternatives)
Suggestion: Use fresh air damper HAC-0
X
10-O
PO
/
PC.
X
= Diameter of damper,
PO
=
P
ower
O
pen,
PC
=
P
ower
C
lose.
Schematic Wire Diagram of ADP-0241-05A
Activated by an Exhaust Fan Auxiliary
Relay Switch and/or Thermostat
Controlling a Furnace Re-circulating Fan,
and a
Power Close
Fresh Air
Damper with
Relay
.
Damper also opens during furnace
firing.
Suggestion:
Use Fresh Air
Damper with Relay
HAC – 0
X
1
1
– O
PC
where
X
= Diameter of Damper,
1
= Relay,
PC
=
P
ower
C
lose
Note:
For PC damper only, a toggle switch in
series with 24Vac electrical supply line to the
Damper will cause it to open as required.
* Note:
For
PC damper without relay
and if
adding a Combustion Air Damper, re-connect
Fresh Air Damper from furnace ‘C’ to Green
wire of the Combustion Air Damper. Both
dampers will open during firing of the furnace.
* Note:
If existing ventilation relay (auxiliary
relay switch) cannot be located, relay wires
presently connected to ‘R’ and ‘G’ of the
furnace are to be re-connected to ‘3’ of ADP
and ‘C’ of the furnace. ADP ‘WHT’ will then
go to ‘G
F
’ of the furnace and ADP ‘RED’ will
go to ‘G
T
’ of the thermostat (if used).
See wiring diagrams.