Hoyme ADP-0241-05A Installation Instructions Download Page 2

1149-ch 

2                                                      Printed in Canada 

SCHEMATIC WIRE DIAGRAM OF 

ADAPTOR ADP- 0241- 05A 

 

 

 

Note: This marking is also on the cover of the 
Adaptor unit as well as on a label to be placed 
next to the wiring diagram of the appliance. 

 
Schematic Wire Diagram of ADP-0241-05A 
Activated by an Exhaust Fan Auxiliary 
Relay Switch To Control a Furnace Re-
circulating Fan and a Fresh Air Damper.  

Damper remains closed during furnace firing. 
(See 

‘Notes’

 for alternatives) 

 

 

Suggestion: Use fresh air damper HAC-0

X

10-O

PO

/

PC.

  

X

 = Diameter of damper, 

PO

P

ower 

O

pen,  

PC

P

ower 

C

lose. 

 

 

Schematic Wire Diagram of ADP-0241-05A 
Activated by an Exhaust Fan Auxiliary 
Relay Switch and/or Thermostat 
Controlling a Furnace Re-circulating Fan, 
and a 

Power Close

 Fresh Air 

Damper with 

Relay

Damper also opens during furnace 

firing. 

 

 
 

 

Suggestion:

 

Use Fresh Air 

Damper with Relay

   

HAC – 0

X

1

1

 – O

PC

 where 

X

 = Diameter of Damper,  

1

 = Relay, 

PC

 = 

P

ower 

C

lose 

       

Note:

 For PC damper only, a toggle switch in 

series with 24Vac electrical supply line to the 
Damper will cause it to open as required.  
 

* Note:

 For

 

PC damper without relay

 and if 

adding a Combustion Air Damper, re-connect 
Fresh Air Damper from furnace ‘C’ to Green 
wire of the Combustion Air Damper. Both 
dampers will open during firing of the furnace. 
  

* Note: 

If existing ventilation relay (auxiliary 

relay switch) cannot be located, relay wires 
presently connected to ‘R’ and ‘G’ of the 
furnace are to be re-connected to ‘3’ of ADP 
and ‘C’ of the furnace.  ADP ‘WHT’ will then 
go to ‘G

F

’ of the furnace and ADP ‘RED’ will 

go to ‘G

T

’ of the thermostat (if used).  

See wiring diagrams.  

 

HMI 

HOYME Manufacturing Inc.                1-800-661-7382                             www.hoyme.com 