Hoyme ADP-0241-05A Installation Instructions Download Page 1

1149-ch 

1                                                      Printed in Canada 

Installation Instructions for 

HMI

 HOYME 

Adaptor 0241- 05A 

24Vac Controlled Voltage      -       Switches 24Vac/ 120Vac 

  

INSTALLATION OF THIS ADAPTOR SHALL BE 
IN ACCORDANCE WITH THE REQUIREMENTS 
OF THE AUTHORITIES HAVING JURISDICTION

 

 
Refer also to HOYME Installation Instructions: 
Combustion Air Control Damper, Series HOM;  
Replacement/Ventilation Air Control Damper, 
Series HAC; and Adaptor ADP- 1101- 05A. 

 

 

ADP-0241-05A 

            

    

 

                           

4” x 5” x 2 1/2” 

                        101 x 127 x 64 mm 

 

This Relay Adaptor may be used as an automatic 
switch having a 

24Vac Coil

 and 

120Vac points

 to 

control a line voltage circuit for up to a 5 amp 
draw such as a 120Vac exhaust fan. All the points 
can also be used for 24Vac switching. (See wire 
diagrams on next page.) 
 
A typical application where all the points are used 
for 24Vac switching may occur when dry points 
are used at the exhaust fan switch. When the 
exhaust fan switch is turned on, the furnace fan 
and the fresh air damper, if used, will open 
simultaneously. The fresh air damper, however, 
will not open for furnace firing.   

 
If the damper is required to open when the 
appliance fires:  
 
a) 

Refer to wiring diagram (next page) showing 

the

 Power Close Damper with Relay;  

- or - 

b) 

Use a 

regular fresh air damper

 with an

 ADP-

0242-05A 

and follow its Installation Instructions;   

- or - 

c)

 If controlled line voltage is available from the 

exhaust fan, use 

Adaptor ADP-1102-TWP

 and 

follow its installation instructions. 

Fitness of this Adaptor/Damper combination, 
to satisfy air supply requirements for fuel fired 
appliances during operation of the 

 

Inter-connected exhaust fan(s), shall be  
investigated by the enforcing authorities. 

 
Air intake duct installation shall be in accordance 
with: In Canada - CAN/CSA B149 & B139; In the 
USA – ANSI/NFPA 54, 2006, ANSI Z223.1 and/or 
local codes including local codes relating to 
ventilation air duct installation.  
 

I.D.: ADP-0241-05A

; comes with one relay. 

DPDT-Coil-24Vac. Pts-24V & 120Vac- 5Amps. 
 
- One adaptor is required for each heating 
appliance.   
- Adaptor line voltage leads, connected to the  
appliance shall be suitably cabled, fastened and 
enclosed in suitable raceways. 
- Refer to local and applicable codes. 
- If an auxiliary transformer is required, use an 
approved 24Vac transformer of adequate 
capacity. 
- Supply for the transformer primary shall be    
taken from the line voltage supply of the  
appliance. Refer to applicable codes. 
- Always conduct a thorough check-out after  
installation is complete. 
- Affix appropriate labels and follow  
instructions and warnings on each label. 
 
1. Install motorized air control damper as per  
instructions supplied with it. Satisfactory  
operation of the damper is recommended  
before interconnecting Adaptor. 
2. Turn off electrical power supply to the  
appliance. 
3. Connect Adaptor line voltage leads to fan motor 
circuit as per wiring diagram and applicable 
codes. 
4. Connect 24Vac Damper terminal wires to 
appropriate Adaptor, transformer and control 
switches. (See damper wiring diagram for proper 
circuit.) 
5. Turn on electrical power to 24Vac transformer.  
If damper is a Power Open type, it will remain 
closed at this time. If damper is a Power Close 
type, it will close at this time. 
6. Turn on selected switches at least 3 times to 
verify the intended operation of selected circuits. 

 