SETTING UP THE PRODUCT AND COMMUNICATING CHANNEL 

There is a red control diode 

RUN

 flashing.

Press the 

SET

 button on the control unit until the red control diode turns off.

Remove the strip between the battery and the contact in the display. It prevents 
the batteries to power the display. In case, the display is already powered, 
remove and after short moment put back inside all the batteries.
                                       
The first number from the product codes appears on the 
display (list of product codes on page 13).

Scroll to the required number by short presses of the 

SET

 

button.  To confirm the selection hold the 

SET

 button for 5 sec.

  

Now the last two numbers  from the product codes are active. Scroll to the 
required number by short presses of the 

SET

 button.  To confirm the selection 

hold the 

SET

 button for 5 sec. 

Now the number of the communicating channel is active. 

Confirm by holding the

 SET

 button. In case there is another 

fireburning control installed or another source interfering the 

communication, repeat the 

SET-UP

 process and choose 

different channel.
 
Set message appears on the display to confirm the set-up 
proces was finished succesfully. After a while the fireburning 
control turns itself into operating mode.

SET-UP

SHORT PRESS TO CHANGE VALUE. 
HOLD TO CONFIRM THE CHOICE.

1

2

3

4

5

6

7

8

RUN

SET

S1

TK

T1

12V DC

PWR

8

Summary of Contents for ABRA 6

Page 1: ...Installation and operating instruction ABRA 6...

Page 2: ...TION Door sensor intallation Page 6 Hightemperature sensor installation Page 6 Air inlet flap installation Page 7 Electronical unit connection Page 7 SETTINGS Setting of device and communication chann...

Page 3: ...he burning chamber this fireburning control optimizes combustion by precise dosage of inlet air The installation of this product must be carried out by specialist stove maker only Before you start usi...

Page 4: ...on RUN Operation control diode Flashing signals ongoing burning process If switches off during set up process it confirms the current step TK Connector input for door sensor Control diode signals clos...

Page 5: ...hitch only compatible with HOXTER products C AIR INLET FLAP Heat resistence of the stainless steel flap and its components max 50 C 122 F Lenght of the cable 4m 13 ft heat resistence of the cable 180...

Page 6: ...e magnetic counterpart on the bottom edge of the doors Both the door sensor and the magnetic counterpart must be placed in the common axis The distance between those parts must be 2 12mm 0 08 0 47 in...

Page 7: ...inlet flap and the product must be tight enough When installing into closed in build the air inlet flap must be placed outside the hightemperature place The heat resistence of the air inlet flap is ma...

Page 8: ...To confirm the selection hold the SET button for 5 sec Now the last two numbers from the product codes are active Scroll to the required number by short presses of the SET button To confirm the selec...

Page 9: ...he product and communicating channel After confirmation of the UNI product code the option for temperature T5 appears on the display When this temperature is reached the air inlet flap is closing comp...

Page 10: ...er part During common operation the display shows four basic values Current temperature in the burning chambre Temperature measured by the hightemperature sensor Time of burning The period starts when...

Page 11: ...erature in the burning chamber didn t reach 90 C and decreased of more than 10 C The fireburning control automatically ends the combustion proces and when the temperature drops bellow 50 C it closes t...

Page 12: ...in set up mode Remove and put back batteries from the display Finish the set up process Display is showing SIG control diode PWR is on control diode RUN is flashing Display is out of reach from the e...

Page 13: ...1 04 HAKA 89 45h 1 05 ECKA 67 45 51h 1 06 ECKA 90 40 40h 1 07 HAKA 37 50W 1 08 HAKA 63 51W 1 09 HAKA 63 51WT 1 10 HAKA 67 38W 1 11 HAKA 67 51W 1 12 HAKA 89 45Wh 1 13 ECKA 67 45 51Wh UNIVERSAL 2 01 UNI...

Page 14: ...n t apply if the damaged products were exposed to temperatures higher than the defined maximal values Installation of the electronical fireburning control ABRA 6 must be done by specialist stove maker...

Page 15: ...NOTES 15...

Page 16: ...OXTER gmbh Kirchgasse 1 91217 Hersbruck Germany Tel 49 0 9151 8659 163 info hoxter de www hoxter de HOXTER a s Ml nsk 326 13 602 00 Brno Czech republic Tel 420 518 777 701 info hoxter eu www hoxter eu...

Reviews: