hoxter ABRA 6 Installation And Operating Instruction Download Page 6

 

DOOR SENSOR INSTALLATION

 

Break out the indicated opening in the steel 
hitch 

(B)

, pull the door sensor through this hole 

(A)

 and fasten with the distance barrel 

(C)  

and a nut 

(D)

 

Fasten the steel hitch with the door sensor  
on designed place at the frame 

(E)

.

  

 
 

Enclose the magnetic counterpart on the 
bottom edge of the doors.  
 
 

Both the door sensor and the magnetic 
counterpart must be placed in the common 
axis. The distance between those parts 
must be 2-12mm  / 0.08-0.47 in. 

(F) 

In case 

the distance between these part is too big, 
underlay the magnetic counterpart with the 
distance barrel. 
  

The magnetic counterpart is strong enough  
to held on place. For the fixation use  
enclosed screws 

(G)

.

A

B
C

D

E

INSTALLATION

1

2

3

4

5

2-12 mm

F

6

G

Summary of Contents for ABRA 6

Page 1: ...Installation and operating instruction ABRA 6...

Page 2: ...TION Door sensor intallation Page 6 Hightemperature sensor installation Page 6 Air inlet flap installation Page 7 Electronical unit connection Page 7 SETTINGS Setting of device and communication chann...

Page 3: ...he burning chamber this fireburning control optimizes combustion by precise dosage of inlet air The installation of this product must be carried out by specialist stove maker only Before you start usi...

Page 4: ...on RUN Operation control diode Flashing signals ongoing burning process If switches off during set up process it confirms the current step TK Connector input for door sensor Control diode signals clos...

Page 5: ...hitch only compatible with HOXTER products C AIR INLET FLAP Heat resistence of the stainless steel flap and its components max 50 C 122 F Lenght of the cable 4m 13 ft heat resistence of the cable 180...

Page 6: ...e magnetic counterpart on the bottom edge of the doors Both the door sensor and the magnetic counterpart must be placed in the common axis The distance between those parts must be 2 12mm 0 08 0 47 in...

Page 7: ...inlet flap and the product must be tight enough When installing into closed in build the air inlet flap must be placed outside the hightemperature place The heat resistence of the air inlet flap is ma...

Page 8: ...To confirm the selection hold the SET button for 5 sec Now the last two numbers from the product codes are active Scroll to the required number by short presses of the SET button To confirm the selec...

Page 9: ...he product and communicating channel After confirmation of the UNI product code the option for temperature T5 appears on the display When this temperature is reached the air inlet flap is closing comp...

Page 10: ...er part During common operation the display shows four basic values Current temperature in the burning chambre Temperature measured by the hightemperature sensor Time of burning The period starts when...

Page 11: ...erature in the burning chamber didn t reach 90 C and decreased of more than 10 C The fireburning control automatically ends the combustion proces and when the temperature drops bellow 50 C it closes t...

Page 12: ...in set up mode Remove and put back batteries from the display Finish the set up process Display is showing SIG control diode PWR is on control diode RUN is flashing Display is out of reach from the e...

Page 13: ...1 04 HAKA 89 45h 1 05 ECKA 67 45 51h 1 06 ECKA 90 40 40h 1 07 HAKA 37 50W 1 08 HAKA 63 51W 1 09 HAKA 63 51WT 1 10 HAKA 67 38W 1 11 HAKA 67 51W 1 12 HAKA 89 45Wh 1 13 ECKA 67 45 51Wh UNIVERSAL 2 01 UNI...

Page 14: ...n t apply if the damaged products were exposed to temperatures higher than the defined maximal values Installation of the electronical fireburning control ABRA 6 must be done by specialist stove maker...

Page 15: ...NOTES 15...

Page 16: ...OXTER gmbh Kirchgasse 1 91217 Hersbruck Germany Tel 49 0 9151 8659 163 info hoxter de www hoxter de HOXTER a s Ml nsk 326 13 602 00 Brno Czech republic Tel 420 518 777 701 info hoxter eu www hoxter eu...

Reviews: