Before cleaning or attempting any type of maintenance, always make sure that the electricity 

supply is disconnected.

To avoid the possibility of fire, adhere strictly to all of the recommendations included in this 

booklet, paying particular attention to the grease filters to ensure grease deposits do not build up.

The manufacturer declines all liability in cases where the instructions for the appropriate installation, 
maintenance and use of the extractor hood are not observed.

If the power cable is cut or damaged in any way, disconnect the extractor from the electricity supply and call 

the service number on the rear cover of this booklet or a suitably qualified repairer.

General Cleaning        

  

 

 

                                      

Wipe the external surfaces of the appliance regularly using warm water and a mild detergent. NEVER use 
abrasive cleaners.

Care and maintenance  

The Grease Filters 

     

                 

The grease filter is of a metallic material and should 

be washed using a neutral detergent.

To Remove the grease filters:

1 Push latch 

2 Lower filter to remove.

The  Carbon  Filters 

 

                             

Carbon filters have a limited life. We advise you 

to change them when there is a noticeable drop 
in performance. The intervals between changing 

the filter will depend entirely upon the amount of 

cooking you do, but on average they will last about 
6 months. Please quote the part refrence number  
HJA2910 (pack of 2) when re-ordering.

• 

To gain access to the carbon filters, first of all 

remove the grease filters as above. 

• 

Remove the old filters and install new charcoal 

filters by turning them gently

1

2

1

2

3

Summary of Contents for Lamona LAM2400

Page 1: ...User Installation Guide LAM2400 LAM2402 Stainless Steel Chimney Extractor...

Page 2: ...age Warning for possible hazards to health and property Warning possibility of electric shock This product s packaging material is recyclable Help recycle it and protect the environment by dropping it...

Page 3: ...n 04 Extractor layout 04 Control panel layout 04 Care and maintenance 05 General Cleaning 05 Grease Filters 05 Carbon Filters 05 Replacing the Lamps 06 Installation 07 Methods of extraction 07 Extract...

Page 4: ...red by the use of alcohol and or drugs Product must be disconnected from the mains during installation maintenance cleaning and repair procedures Repair procedures must always be performed by qualifie...

Page 5: ...n vent 3 Lower chimney section 4 Fan and light controls 5 Extractor body 6 Grease filters 7 Light General Information operation 0 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Extractor layout Control panel layout 1...

Page 6: ...r a suitably qualified repairer General Cleaning Wipe the external surfaces of the appliance regularly using warm water and a mild detergent NEVER use abrasive cleaners Care and maintenance The Grease...

Page 7: ...ower is switched off and the lamps have had time to cool Remove the grease filters to gain access Unscrew the lamps and replace with new lamps of the same type and wattage Lamp replacement is not cove...

Page 8: ...ion Via Ducting Never use the hood in areas where devices with exhaust pipes connected to the outside are already operating unless perfect ventilation can be guaranteed Connect the external ducting ki...

Page 9: ...FICATION On opening your box you will find the extractor body a two piece telescopic decorative chimney two fixing brackets and ducting connector and reducer 1 Main Extractor Body 2 Lower Chimney 3 Up...

Page 10: ...hen the extractor is used in the same room as appliances supplied with energy other than electricity Never duct into a hot air flow such as a central heating duct We strongly advise that all exterior...

Page 11: ...in extractor body and extend the upper section to the ceiling Use the extended chimney to mark up the position of the upper fixing bracket 5 Remove the chimney section drill and fix the upper fixing b...

Page 12: ...The terminations labelled SUPPLY are the connections for the internal house wiring and the terminations labelled LOAD are for connection to the appliance IMPORTANT The wires in the mains lead are col...

Page 13: ...nsure any venting is not obstructed Clean the grease filters with warm water and mild detergent and or replace any charcoal filters The extractor works normaly but smells linger Clogged filters can re...

Page 14: ...y installed and operated in accordance with the manufacturer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alternations which are likel...

Page 15: ...Exclusive to Howdens Joinery co Page _ 15 User manual LAM2400 LAM2402 Notes...

Page 16: ...If supplied please stick your self adhesive product rating plate here or make a note of the product serial number below in the box below for future reference Serial Number...

Reviews: