www.howdens.com
Page _ 10
LAMONA
Appliances
Hanging Your Extractor
This instruction must be strictly adhered to. Failure to comply could result in overheating and
serious damage to your appliance. It is recommended that the installation is carried out by two people.
Before drilling or chiselling the ceiling or wall, check for pipes and power cables.
•
If ducting externally ensure the ducting tube is kept as short as possible and with the minimum
of bends to permit the smoothest airflow. (Maximum length 3 metres.). Ducted air must not be
discharged into a flue, which is used for exhausting fumes from appliances supplied with energy other
than electricity. (E.g. gas boilers)
•
Ensure the requirements of the local authorities are adhered to concerning the discharge of exhaust
air.
•
Ensure adequate room ventilation is provided when the extractor is used in the same room as
appliances supplied with energy other than electricity.
•
Never duct into a hot air flow such as a central heating duct
We strongly advise that all exterior outlets be fitted with a non return flap or louvred slatting.
700 mm Minimum distance to worktop
750 mm Recommended distance to worktop
**
**
**
**
**
Worktop
Wall
228mm
(**)
Please use rawl plugs and screws appropriate
to the type of wall (not supplied)
700 mm Minimum distance to worktop
750 mm Recommended distance to worktop
40 mm
275 mm
195 mm
Please use rawl plugs and screws
appropriate to the type of wall
Wall
=
=
2
1
2
3
1.
9.
9.
9.
8.
8.
8.
6.
700 mm Minimum distance to worktop
750 mm Recommended distance to worktop
200 mm
50 mm
128 mm
190 mm
105 mm
110 mm
Please use rawl plugs and screws
appropriate to the type of wall
**
•
Remove the grease filters before trying to install.
•
The recommended fixing height for the hood is 750mm above the worktop. This can be reduced to a
minimum of 700mm if required.
•
Mark and drill the holes required to mount the extractor body.
•
The principal securing point is the top keyhole slot; fix this screw first leaving approximately 5mm
between the screw head and the wall.
•
With the help of an assistant, level and secure in position through the lower two holes tightening the
upper screws as necessary.